Fluke 51 II Handheld Digital Probe Thermometer
Key features
- Single Input digital thermometer for lab, QA, process calibration, food safety and HVAC
- Measures J, K, T, and E-type thermocouples
- Presents results in °C, °F, or Kelvin (K) on a large backlit display
- Includes a relative time clock on MIN, MAX, and AVG to provide a time reference for major events
Fluke 51-2 CAL Single Input Digital Thermometer with calibration certificate
Features
- Convenient front panel and large display
- Handheld design provides easy portability and comfort
- Compatible with J, K, T and E-type sensors for temperature measurements
- Rugged design provides long term durability
Fluke 5128A RHapid-Cal® Humidity Generator
- Best-in-class system accuracy for dependable humidity probe calibration
- Rapid humidity and temperature stabilization time for high calibration throughput
- Supports on-site, multi-point calibration of humidity probes
- Versatile design accommodates a large workload
- Compact size and lightweight for easy transport
- ISO 17025 accredited system calibration included standard
- Easy to maintain
Fluke 52-2 CAL Dual Input Digital Thermometer with calibration certificate
Features
- Integrated display and user-friendly panel
- Handheld thermometer allows access to any part of the workplace
- Uses J, K, T and E sensors to gather temperature data
- Provides quick measurements of operation equipment
Fluke 52-II Dual Input Digital Thermometer
Measure contact temperature on motors, insulation, breakers, pipes, corroded connections, liquids, and wires with industrial standard J, K, T, or
Fluke 52120A Transconductance Amplifier
52120A performance at a glance
- Industry-leading amplifier accuracy:
- – 140 ppm ac (used with 61XXA Electrical Power Standard or 5730A)
- – 350 ppm ac (used with dc/lf calibrator
- – 160 ppm dc (used with dc/lf calibrator
- Frequency: DC to 10 kHz
- Burden voltage (compliance): 4.5 V @ 120 A
- Inductive drive capability: 1 mH load
- Output ranges: 2 A, 20 A, 120 A
- Input ranges: 2 V or 200 mA F.S. for 2 A and 20 A ranges, 1.2 V or 120 mA F.S. for 120 A range
- Parallel operation: (Closed loop mode with 61XXX or 5730A) 2 or 3 amplifiers, up to 360 A in a single phase
- Parallel operation: (Standalone mode), up to 10 amplifiers, up to 1200 A in a single phase
- Accessory coils: 25-turn coil supports 3000 A, 50-turn coil supports 6000 A
- Control communication with 6105A/6100B Electrical Power Standards or 5730A
- GPIB remote operation
Fluke 525B Temperature/Pressure Calibrator
- Simulates and measures all ANSI thermocouples, as well as L and U types, and provides cold junction compensation to enable calibration of a wide variety of thermocouple instrumentation.
- Direct input for storage of ITS-90 RTD constants.
- RTD source uncertainties to 0.03° C
- Extend pressure measurement range with any Fluke 750P and 700P Series Pressure Modules
- Converts easily to any pressure unit directly from the front panel or through remote communications.
- Sources dc voltage and current for multifunction workload coverage, enabling calibration of data loggers, strip chart recorders, multimeters, and other industrial instruments.
- Supports automation using MET/CAL® Plus Calibration Management Software or custom automated programs with standard RS-232-C and GPIB interface.
- Eight user programmable setpoints allow quick recall of values for Zero, Span and linearity checks during calibration. Programmable setpoint dwell times for automated calibration and troubleshooting.
- Programmable setpoint dwell times for automated calibration and troubleshooting.
- Selectable internal or external CJC (cold junction compensation) provides you with the ability to make exacting thermocouple measurements using remote junctions.
- Easy five-way binding posts for low-loss convenient hookup. Banana plug, screw terminal, spade lug, wraparound terminal, wire pass-through terminal.
- NIST-traceable calibration with data is included
Fluke 53-2-B Single Input Digital Thermometer with data logging
Features
- Single input digital thermometer with data logging
- Logs up to 500 points of data at user adjustable recording intervals
- Measures J, K, T, E, R, S, and N-type thermocouples
- Presents results in °C, °F, or Kelvin (K) on a large backlit display
- Provides a recall function to easily review logged data
- Easy-to-access battery door that allows replacing the battery without breaking the calibration seal
- Powered by three, standard AA batteries
- Includes a real-time clock that captures the exact event time
- Infrared USB communication port allows data to be exported to optional FlukeView Forms® Temperature PC software for further analysis and graphing
- Includes an electronic offset function that compensates for thermocouple errors to maximize overall accuracy
- Handles temperatures up to >1600°F (900°C)
- Provides a user-friendly front panel that is easy to set up and operate
- Offers sleep mode to increase battery life; 1000-hour battery life typical
Applications
- Lab
- QA
- Process calibration
- Food safety
- HVAC/R
Fluke 5322A Electrical Safety Tester Calibrator
The 5322A calibrates a broad range of equipment, including:
- Hipot testers
- Insulation resistance testers (megohm-meters) including older analog testers
- Loop/line impedance testers
- Continuity testers
- Earth resistance testers
- Ground bond testers
- Leakage current testers
- Circuit breaker testers (RCD/GFCI)
- Multifunction installation testers
- Portable appliance testers (PATs)
Fluke 54-2-B Dual Input Digital Thermometer with data logging
Features
- Large backlit dual display shows any combination of T1, T2, plus MIN, MAX, or AVG
- Recall function allows logged data to be easily reviewed on the meter display
- Infrared USB communication port allows data to be exported to optional FlukeView Forms® Temperature PC software for further analysis and graphing
- Data logging up to 500 points of data with user adjustable recording interval
- Relative time clock on MIN, MAX, and AVG provides a time reference for major events
- Electronic Offset function allows compensation of thermocouple errors to maximize overall accuracy
- Measures J, K, T, E, R, S, and N-type thermocouples
- Readout in °C, °F, or Kelvin (K)
- Splash and dust resistant case protected by impact absorbing holster
- User-friendly front panel is easy to set up and operate
- Sleep mode increases battery life; typical 1000-hour battery life
- Battery door allows easy battery replacement without breaking the calibration seal
Applications
- Lab
- QA
- Process calibration
- Food safety
- HVAC/R
Fluke 5430 Standard AC/DC Resistors
- Long-term stability better than 2 ppm/year (< 1 ppm typical)
- Traceable AC and DC calibrations available
- National lab design proven for more than 25 years