Fluke 5609-9BND-P Secondary PRT with 90° Bend and INFO-CON for 1523/1524 Models, Calibration Options
Features
- -328 to 1,238°F (-200 to 670°C) (3.94in (100mm) minimum immersion)
- ±0.01 short-term stability
- Calibration not included, NVLAP-accredited calibration optional, lab code 200348-0
Fluke 5609-9BND-S Secondary PRT with 90° Bend and Spade Lugs, Calibration Options
What’s included with the Fluke 5609-9BND-S
- Fluke 5609-9BND-S Secondary PRT with 90° Bend and Spade Lugs, Calibration Options
Fluke 561 HVAC Infrared & Contact Thermometer
- IR thermometer for quick measurements up close, or at a distance, without a ladder
- Contact thermometry capability, compatible with all standard mini-connector K-type thermocouples, preserves your investment in thermocouples
- Velcro® pipe probe for superheat and sub-cooling and other contact and ambient measurements
- Single-point laser sighting
- Easy emissivity adjustment for measuring pipes and other shiny materials more accurately
- Lightweight and portable
- Very easy to use
- Efficient—no need to shut down equipment when making IR measurements
- MIN, MAX, and DIF functions help you quickly identify problems
- Scan large areas or small objects quickly and efficiently
Fluke 5610-6-B Secondary Reference Thermistor Probe with Bare Wire
Features
- Short-term accuracy to ±0.01°C; 1-year drift <±0.01°C
- Accredited NVLAP calibration optional
- Flexible PTFE and silicone-coated, fast-response models
Fluke 5610-6-D Secondary Reference Thermistor Probe with 5-Pin DIN for Tweener Thermometers
Features
- Short-term accuracy to ±0.01°C; 1-year drift <±0.01°C
- Accredited NVLAP calibration optional
- Flexible PTFE and silicone-coated, fast-response models
Fluke 5610-6-G Secondary Reference Thermistor Probe with Gold Pins
Features
- Short-term accuracy to ±0.01°C; 1-year drift <±0.01°C
- Accredited NVLAP calibration optional
- Flexible PTFE and silicone-coated, fast-response models
Fluke 5610-6-J Secondary Reference Thermistor Probe with Banana Plugs
Features
- Short-term accuracy to ±0.01°C; 1-year drift <±0.01°C
- Accredited NVLAP calibration optional
- Flexible PTFE and silicone-coated, fast-response models
Fluke 5610-6-L Secondary Reference Thermistor Probe with Mini Spade Lugs
Features
- Short-term accuracy to ±0.01°C; 1-year drift <±0.01°C
- Accredited NVLAP calibration optional
- Flexible PTFE and silicone-coated, fast-response models
Fluke 5610-6-M Secondary Reference Thermistor Probe with Mini Banana Plugs
Features
- Short-term accuracy to ±0.01°C; 1-year drift <±0.01°C
- Accredited NVLAP calibration optional
- Flexible PTFE and silicone-coated, fast-response models
Fluke 5610-6-P Secondary Reference Thermistor Probe with INFO-CON for 1523/1524 Models
Features
- Short-term accuracy to ±0.01°C; 1-year drift <±0.01°C
- Accredited NVLAP calibration optional
- Flexible PTFE and silicone-coated, fast-response models
Fluke 5610-6-S Secondary Reference Thermistor Probe with Spade Lugs
Features
- Short-term accuracy to ±0.01°C; 1-year drift <±0.01°C
- Accredited NVLAP calibration optional
- Flexible PTFE and silicone-coated, fast-response models
Fluke 5610-9-B Secondary Reference Thermistor Probe with Bare Wire, 6ft Lead
Features
- Short-term accuracy to ±0.01°C; 1-year drift <±0.01°C
- Accredited NVLAP calibration optional
- Flexible PTFE and silicone-coated, fast-response models