-10%
Close
Fluke 6531-40M E DWT Electronic Deadweight Tester, 40 mPa, 6K PSI
Fluke 6531-40M Offers
Features
- No weights to load and unload, transport or send out for calibration
- Provides real-time pressure indication with no need to know and correct for local gravity or ambient temperature
- No piston-cylinder changes
- No significant sensitivity to level or vibration
- Able to set and read any pressure value exactly, no minimum increment limited by smallest available masses; perfect for applications that require setting a nominal pressure precisely on the device under test and measuring it, such as analog gauge calibration
- Operates in any unit of measure, switching easily from one unit to the next
-10%
Close
Fluke 6531-70M E DWT Electronic Deadweight Tester, 70 mPa, 10K PSI
Fluke 6531-70M Offers
Features
- No weights to load and unload, transport or send out for calibration
- Provides real-time pressure indication with no need to know and correct for local gravity or ambient temperature
- No piston-cylinder changes
- No significant sensitivity to level or vibration
- Able to set and read any pressure value exactly, no minimum increment limited by smallest available masses; perfect for applications that require setting a nominal pressure precisely on the device under test and measuring it, such as analog gauge calibration
- Operates in any unit of measure, switching easily from one unit to the next
-10%
Close
Fluke 6531-70M E DWT Electronic Deadweight Tester, 70 mPa, 10K PSI
Fluke 6531-70M Offers
Features
- No weights to load and unload, transport or send out for calibration
- Provides real-time pressure indication with no need to know and correct for local gravity or ambient temperature
- No piston-cylinder changes
- No significant sensitivity to level or vibration
- Able to set and read any pressure value exactly, no minimum increment limited by smallest available masses; perfect for applications that require setting a nominal pressure precisely on the device under test and measuring it, such as analog gauge calibration
- Operates in any unit of measure, switching easily from one unit to the next
-10%
Close
Fluke 6531-7M E DWT Electronic Deadweight Tester, 7 mPa, 1K PSI
Fluke 6531-7M Offers
Features
- No weights to load and unload, transport or send out for calibration
- Provides real-time pressure indication with no need to know and correct for local gravity or ambient temperature
- No piston-cylinder changes
- No significant sensitivity to level or vibration
- Able to set and read any pressure value exactly, no minimum increment limited by smallest available masses; perfect for applications that require setting a nominal pressure precisely on the device under test and measuring it, such as analog gauge calibration
- Operates in any unit of measure, switching easily from one unit to the next
Fluke 6531, 6532 E-DWT Electronic Deadweight Tester Kits
- No weights to load and unload, transport or send out for calibration
- Provides real-time pressure indication with no need to know and correct for local gravity or ambient temperature
- No piston-cylinder changes
- No significant sensitivity to level or vibration
- Able to set and read any pressure value exactly, no minimum increment limited by smallest available masses; perfect for applications that require setting a nominal pressure precisely on the device under test and measuring it, such as analog gauge calibration
- Operates in any unit of measure, switching easily from one unit to the next
-10%
Close
Fluke 6532-140M E DWT Electronic Deadweight Tester, 1.4 to 140 mPa, 200 to 20 000 PSI
Fluke 6532-140M Offers
Features
- No weights to load and unload, transport or send out for calibration
- Provides real-time pressure indication with no need to know and correct for local gravity or ambient temperature
- No piston-cylinder changes
- No significant sensitivity to level or vibration
- Able to set and read any pressure value exactly, no minimum increment limited by smallest available masses; perfect for applications that require setting a nominal pressure precisely on the device under test and measuring it, such as analog gauge calibration
- Operates in any unit of measure, switching easily from one unit to the next
-10%
Close
Fluke 6532-200M-B E-DWT Electronic Deadweight Tester, 4 to 200 mPa, 600 to 30,000 PSI
Features
- No weights to load and unload, transport or send out for calibration
- Provides real-time pressure indication with no need to know and correct for local gravity or ambient temperature
- No piston-cylinder changes
- No significant sensitivity to level or vibration
- Able to set and read any pressure value exactly, no minimum increment limited by smallest available masses; perfect for applications that require setting a nominal pressure precisely on the device under test and measuring it, such as analog gauge calibration
- Operates in any unit of measure, switching easily from one unit to the next
-10%
Close
Fluke 6532-70M E DWT Electronic Deadweight Tester, 0.7 to 70 mPa, 100 to 10 000 PSI
Fluke 6532-70M Offers
Features
- No weights to load and unload, transport or send out for calibration
- Provides real-time pressure indication with no need to know and correct for local gravity or ambient temperature
- No piston-cylinder changes
- No significant sensitivity to level or vibration
- Able to set and read any pressure value exactly, no minimum increment limited by smallest available masses; perfect for applications that require setting a nominal pressure precisely on the device under test and measuring it, such as analog gauge calibration
- Operates in any unit of measure, switching easily from one unit to the next
-10%
Close
Fluke 700-IV Current Shunt
Fluke 700-IV Offers
The Fluke 700-IV Current Shunt is used with the 741 or 743 Documenting Process Calibrator to measure and source current simultaneously.
Specifications
- Input current range: 0 to 55 mA DC
- Conversion factor: 1 mA in converts to 10 mV out
- Accuracy (Note): ±0.025% of input
- Calibration interval: 1 year
- Input resistance: 250Ω Nominal
- Output resistance: 10Ω Nominal
- Maximum voltage input: 30V DC
Fluke 7008/ 7040/ 7037/ 7012/ 7011 Refrigerated Temperature Calibration Baths
- Stability to ±0.0007 °C
- Best digital temperature controller available
- “Super Tweak” function provides set-point resolution to 0.00003 °C
- Excellent for maintaining fixed-point cells
Fluke 7009/7108/7015 Resistor Baths
Three size options for any quantity of resistors
- Three size options for any quantity of resistors
- Stability to ±0.0007 °C
- Independent high- and low-temperature cutout circuit
- Minimal long-term drift
-10%
Close
Fluke 700G/TRACK Data Logging Software & Cable
Features
- Enables data download and logging configurations to the 700G Series gauges for a remote logging event
- Configure logging event reading rate, duration and measurement units
- Upload measurements logged remotely and display or export measurements
- Includes communication cable for connection to a PC and CD-Rom user manual
- Manage your instruments and calibration data with this easy-to-use software. For use with 700G Series gauges to perform real time data logging.