Fluke 721EX-3603 Dual Sensor Pressure Calibrator, 36 PSIG/300 PSIG
Features
- Can be configured by selecting either a 16 psi (1.1 bar) or 36 psi (2.48 bar) low pressure sensor then add any of 7 high pressure ranges including 100, 300, 500, 1000, 1500, 3000 or 5000 psi (6.9, 20, 24.5, 69, 103.4, 200, 345 bar)
- Two isolated, stainless steel, pressure sensors with 0.025% accuracy
- Switch test on both pressure inputs
- Pressure displayed in the user’s choice of 19 engineering units: psi, bar, mbar, kPa, kgcm2, cmH2O @ 4°C, cmH2O @ 20°C, mH2O @ 4°C, mH2O @ 20°C, inH2O @ 4°C, inH2O @ 20°C, inH2O @ 60°F, mmHg @ 0°C, inHg @ 0°C, ftH2O @ 4°C, ftH2O @ 20°C, ftH2O @ 60°F
- Precision temperature measurement with optional RTD probe
- Measures 4 to 20 mA signals
- Large backlit graphic display shows up to three inputs simultaneously
- Store five instrument setups for recall and use
Fluke 721EX-3605 Dual Sensor Pressure Calibrator, 36 PSIG/500 PSIG
Features
- Can be configured by selecting either a 16 psi (1.1 bar) or 36 psi (2.48 bar) low pressure sensor then add any of 7 high pressure ranges including 100, 300, 500, 1000, 1500, 3000 or 5000 psi (6.9, 20, 24.5, 69, 103.4, 200, 345 bar)
- Two isolated, stainless steel, pressure sensors with 0.025% accuracy
- Switch test on both pressure inputs
- Pressure displayed in the user’s choice of 19 engineering units: psi, bar, mbar, kPa, kgcm2, cmH2O @ 4°C, cmH2O @ 20°C, mH2O @ 4°C, mH2O @ 20°C, inH2O @ 4°C, inH2O @ 20°C, inH2O @ 60°F, mmHg @ 0°C, inHg @ 0°C, ftH2O @ 4°C, ftH2O @ 20°C, ftH2O @ 60°F
- Precision temperature measurement with optional RTD probe
- Measures 4 to 20 mA signals
- Large backlit graphic display shows up to three inputs simultaneously
- Store five instrument setups for recall and use
Fluke 721EX-3610 Dual Sensor Pressure Calibrator, 36 PSIG/1000 PSIG
Features
- Can be configured by selecting either a 16 psi (1.1 bar) or 36 psi (2.48 bar) low pressure sensor then add any of 7 high pressure ranges including 100, 300, 500, 1000, 1500, 3000 or 5000 psi (6.9, 20, 24.5, 69, 103.4, 200, 345 bar)
- Two isolated, stainless steel, pressure sensors with 0.025% accuracy
- Switch test on both pressure inputs
- Pressure displayed in the user’s choice of 19 engineering units: psi, bar, mbar, kPa, kgcm2, cmH2O @ 4°C, cmH2O @ 20°C, mH2O @ 4°C, mH2O @ 20°C, inH2O @ 4°C, inH2O @ 20°C, inH2O @ 60°F, mmHg @ 0°C, inHg @ 0°C, ftH2O @ 4°C, ftH2O @ 20°C, ftH2O @ 60°F
- Precision temperature measurement with optional RTD probe
- Measures 4 to 20 mA signals
- Large backlit graphic display shows up to three inputs simultaneously
- Store five instrument setups for recall and use
Fluke 721EX-3615 Dual Sensor Pressure Calibrator, 36 PSIG/1500 PSIG
Features
- Can be configured by selecting either a 16 psi (1.1 bar) or 36 psi (2.48 bar) low pressure sensor then add any of 7 high pressure ranges including 100, 300, 500, 1000, 1500, 3000 or 5000 psi (6.9, 20, 24.5, 69, 103.4, 200, 345 bar)
- Two isolated, stainless steel, pressure sensors with 0.025% accuracy
- Switch test on both pressure inputs
- Pressure displayed in the user’s choice of 19 engineering units: psi, bar, mbar, kPa, kgcm2, cmH2O @ 4°C, cmH2O @ 20°C, mH2O @ 4°C, mH2O @ 20°C, inH2O @ 4°C, inH2O @ 20°C, inH2O @ 60°F, mmHg @ 0°C, inHg @ 0°C, ftH2O @ 4°C, ftH2O @ 20°C, ftH2O @ 60°F
- Precision temperature measurement with optional RTD probe
- Measures 4 to 20 mA signals
- Large backlit graphic display shows up to three inputs simultaneously
- Store five instrument setups for recall and use
Fluke 721EX-3630 Dual Sensor Pressure Calibrator, 36 PSIG/3000 PSIG
Features
- Can be configured by selecting either a 16 psi (1.1 bar) or 36 psi (2.48 bar) low pressure sensor then add any of 7 high pressure ranges including 100, 300, 500, 1000, 1500, 3000 or 5000 psi (6.9, 20, 24.5, 69, 103.4, 200, 345 bar)
- Two isolated, stainless steel, pressure sensors with 0.025% accuracy
- Switch test on both pressure inputs
- Pressure displayed in the user’s choice of 19 engineering units: psi, bar, mbar, kPa, kgcm2, cmH2O @ 4°C, cmH2O @ 20°C, mH2O @ 4°C, mH2O @ 20°C, inH2O @ 4°C, inH2O @ 20°C, inH2O @ 60°F, mmHg @ 0°C, inHg @ 0°C, ftH2O @ 4°C, ftH2O @ 20°C, ftH2O @ 60°F
- Precision temperature measurement with optional RTD probe
- Measures 4 to 20 mA signals
- Large backlit graphic display shows up to three inputs simultaneously
- Store five instrument setups for recall and use
Fluke 721EX-3650 Dual Sensor Pressure Calibrator, 36 PSIG/5000 PSIG
Features
- Can be configured by selecting either a 16 psi (1.1 bar) or 36 psi (2.48 bar) low pressure sensor then add any of 7 high pressure ranges including 100, 300, 500, 1000, 1500, 3000 or 5000 psi (6.9, 20, 24.5, 69, 103.4, 200, 345 bar)
- Two isolated, stainless steel, pressure sensors with 0.025% accuracy
- Switch test on both pressure inputs
- Pressure displayed in the user’s choice of 19 engineering units: psi, bar, mbar, kPa, kgcm2, cmH2O @ 4°C, cmH2O @ 20°C, mH2O @ 4°C, mH2O @ 20°C, inH2O @ 4°C, inH2O @ 20°C, inH2O @ 60°F, mmHg @ 0°C, inHg @ 0°C, ftH2O @ 4°C, ftH2O @ 20°C, ftH2O @ 60°F
- Precision temperature measurement with optional RTD probe
- Measures 4 to 20 mA signals
- Large backlit graphic display shows up to three inputs simultaneously
- Store five instrument setups for recall and use
Fluke 724 Temperature Calibrator
Features
- Measure Accuracy
- RTD: .2 to .33°C
- Thermocouples: .7 to 1.8°C
- Voltage DC: 0.025% to 0.02%
- Current DC: 0.02%
- Resistance: 0.1 to 1.5%
- Source Accuracy
- Voltage DC: 0.025 to 0.02%
- Resistance: 0.15Ω to 1Ω
Fluke 725 Multifunction Process Calibrator
Features
- Up to 30V and 24mA DC
- 0 to 3200Ω resistance
- Up to 10kHz frequency
- 1V peak-to-peak-minimum senitivity
- Combine with a 750P module for pressure
- Store frequently used test setups for later use
Fluke 7250, 7250i, and 7250xi Pressure Controller / Calibrators
- Pressure ranges from 0 to 5 and 0 to 3 000 psi (0 to 35 kPa and 0 to 21 MPa)
- Model 7250xi and 7250i provide advanced precision of 0.005 % of reading
- Model 7250 provides 0.003 % of full scale precision
- Stability: 0.0075 % of reading per year
- Time to setpoint: 20 seconds with no overshoot
- Control stability: 10 ppm
- Active matrix color screen with enhanced navigation menus
- Languages: English, French, Chinese, German, Japanese, Spanish and Italian
Fluke 7250LP Low Pressure Controller/Calibrator
- Dual range, select from 10/30 inH2O or 20/60 inH2O or 35/100 inH20 range combinations
- Precision: 0.005 % of reading from 10 % to 100 % Full Scale (FS)
- Control stability: 0.004 % of each range
- Resolution to 0.0001 inH2O
- Time to set point: 30 seconds with no overshoot
- Languages: English, French, Chinese, German, Japanese, Spanish and Italian
Fluke 7250Sys Multi-Range Pressure Calibration System
- Fully integrated multi-range pressure test and calibration systems
- Select either an 8-range or the 12-range system for maximum performance and coverage
- Single test port to connect device under test (DUT)
- Pressure ranges to 2 500 psi (170 bar)
- Internal vacuum pump for absolute mode and negative gauge mode operation. Optional internal gas booster for nitrogen source pressure efficiency
- High speed pressure control provides increased throughput
- Automatic range switching
- MET/CAL® driver available
- Languages: English, French, Chinese, German, Japanese, Spanish and Italian
Fluke 7252, 7252i Dual Output Digital Pressure Controllers
- Dual range controller with independent test ports for each range
- Simultaneous pressure control for each range
- Select any range combination from 0 to 10 inH2O (25 mbar) to 0 to 2500 psi (172 bar).
- Two models to choose from, 7252i or 7252
- Time to setpoint < 15 seconds with no overshoot