Fluke 750P09 Gauge Pressure Module, 0-100 Bar, 3X Burst Rating
Features
- Parameter/Range:0 to 1500 psi (0 to 100 bar)
- Burst Rating6:4X
- Hi Side Media2:316 SS
- Lo Side Media2:N/A
- Reference Uncertainty4:± 0.0175%
- Total Uncertainty 1-year (15-35°C):± 0.035%
- Total Uncertainty 1-year1:± 0.045%
- Total Uncertainty 6-month (15-35°C):± 0.03%
- Total Uncertainty 6-month1:± 0.04%
Applications
- Pressure instrument calibration
- Petro-Chemical
- Oil and Gas
- Pharmaceutical
- Water and wastewater
- Food and Beverage
- Power Generation
Fluke 750P09EX Pressure Module, 1500 PSIG
Features
- Digital communication eliminates errors due to poor connections and electrical interference
- The modules are inherently temperature compensated from 0 to 50°C (32 to 122°F)
- The modules are fully interchangeable because all measurements are completed in the pressure module itself and then communicated to the calibrator in digitized form
- Modules are calibrated independently of the calibrator, and can be used with any 718Ex or 725Ex calibrator
- Each module has its own serial number to maintain independent traceability
- Rugged construction, urethane over molding protects against shock if dropped and seals against dirt, dust, and moisture ingress
- Pressure connections are ⅛” NPT female, easily converted using adapter set
- ¼” NPT Male, ¼” BSP/ISO and M20 male adapters are provided with each pressure module
- Convenient setup, one-meter cable between the pressure module and calibrator reduces the length of connecting tubing to the pressure source
- Three-year warranty, best in class compared to competitors one year warranty
- Added IEC-Ex certification for compliance in extended geographies
Comparing pressure module specifications, it is important to compare both the temperature range the time period the specifications apply. Matching the pressure range to the application is critical for best performance in performing a calibration.
Applications
- Instrument Maintenance
- Control Systems
- Safety Systems
- Process and Environmental Monitors
Fluke 750P2000 Pressure Module
Specifications
- Parameter/Range:0 to 2000 psi (0 to 140 bar)
- Burst Rating6:4X
- Hi Side Media2:316 SS
- Lo Side Media2:N/A
- Reference Uncertainty4:± 0.0175%
- Total Uncertainty 1-year (15-35°C):± 0.035%
- Total Uncertainty 1-year1:± 0.045%
- Total Uncertainty 6-month (15-35°C):± 0.03%
- Total Uncertainty 6-month1:± 0.04%
Fluke 750P22 Pressure Module
Specifications
- Parameter/Range:0 to 1 psi (0 to 70 mBar)
- Burst Rating6:3x
- Hi Side Media2:316 SS
- Lo Side Media2:Dry Air
- Reference Uncertainty4:± 0.050%
- Total Uncertainty 1-year (15-35°C):± 0.1%
- Total Uncertainty 1-year1:± 0.15%
- Total Uncertainty 6-month (15-35°C):± 0.075%
- Total Uncertainty 6-month1:± 0.125%
Fluke 750P23 Differential Pressure Module, 0-350 mBar, 4X Burst Rating
Features
- Parameter/Range:0 to 5 psi (0 to 350 mBar)
- Burst Rating6:4x
- Hi Side Media2:316 SS
- Lo Side Media2:Dry Air
- Reference Uncertainty4:± 0.02%
- Total Uncertainty 1-year (15-35°C):± 0.04%
- Total Uncertainty 1-year1:± 0.05%
- Total Uncertainty 6-month (15-35°C):± 0.035%
- Total Uncertainty 6-month1:± 0.04%
Fluke 750P24 Pressure Module
Specifications
- Parameter/Range:0 to 15 psi (0 to 1 bar)
- Burst Rating6:4X
- Hi Side Media2:316 SS
- Lo Side Media2:Dry Air
- Reference Uncertainty4:± 0.0175%
- Total Uncertainty 1-year (15-35°C):± 0.035%
- Total Uncertainty 1-year1:± 0.045%
- Total Uncertainty 6-month (15-35°C):± 0.03%
- Total Uncertainty 6-month1:± 0.04%
Fluke 750P24EX Pressure Module, 0-15 PSID, WET
Features
- Digital communication eliminates errors due to poor connections and electrical interference
- The modules are inherently temperature compensated from 0 to 50°C (32 to 122°F)
- The modules are fully interchangeable because all measurements are completed in the pressure module itself and then communicated to the calibrator in digitized form
- Modules are calibrated independently of the calibrator, and can be used with any 718Ex or 725Ex calibrator
- Each module has its own serial number to maintain independent traceability
- Rugged construction, urethane over molding protects against shock if dropped and seals against dirt, dust, and moisture ingress
- Pressure connections are ⅛” NPT female, easily converted using adapter set
- ¼” NPT Male, ¼” BSP/ISO and M20 male adapters are provided with each pressure module
- Convenient setup, one-meter cable between the pressure module and calibrator reduces the length of connecting tubing to the pressure source
- Three-year warranty, best in class compared to competitors one year warranty
- Added IEC-Ex certification for compliance in extended geographies
Comparing pressure module specifications, it is important to compare both the temperature range the time period the specifications apply. Matching the pressure range to the application is critical for best performance in performing a calibration.
Applications
- Instrument Maintenance
- Control Systems
- Safety Systems
- Process and Environmental Monitors
Fluke 750P27 Gauge Pressure Module, 0-20 Bar, 4X Burst Rating
Features
- Parameter/Range:0 to 300 psi (0 to 20 bar)
- Burst Rating6:4X
- Hi Side Media2:316 SS
- Lo Side Media2:N/A
- Reference Uncertainty4:± 0.0175%
- Total Uncertainty 1-year (15-35°C):± 0.035%
- Total Uncertainty 1-year1:± 0.045%
- Total Uncertainty 6-month (15-35°C):± 0.03%
- Total Uncertainty 6-month1:± 0.04%
Applications
- Pressure instrument calibration
- Petro-Chemical
- Oil and Gas
- Pharmaceutical
- Water and wastewater
- Food and Beverage
- Power Generation
Fluke 750P27EX Pressure Module, 300 PSIG
Features
- Digital communication eliminates errors due to poor connections and electrical interference
- The modules are inherently temperature compensated from 0 to 50°C (32 to 122°F)
- The modules are fully interchangeable because all measurements are completed in the pressure module itself and then communicated to the calibrator in digitized form
- Modules are calibrated independently of the calibrator, and can be used with any 718Ex or 725Ex calibrator
- Each module has its own serial number to maintain independent traceability
- Rugged construction, urethane over molding protects against shock if dropped and seals against dirt, dust, and moisture ingress
- Pressure connections are ⅛” NPT female, easily converted using adapter set
- ¼” NPT Male, ¼” BSP/ISO and M20 male adapters are provided with each pressure module
- Convenient setup, one-meter cable between the pressure module and calibrator reduces the length of connecting tubing to the pressure source
- Three-year warranty, best in class compared to competitors one year warranty
- Added IEC-Ex certification for compliance in extended geographies
Comparing pressure module specifications, it is important to compare both the temperature range the time period the specifications apply. Matching the pressure range to the application is critical for best performance in performing a calibration.
Applications
- Instrument Maintenance
- Control Systems
- Safety Systems
- Process and Environmental Monitors
Fluke 750P29 High Pressure Module, 0-200 Bar, 3X Burst Rating
Features
- Parameter/Range:0 to 3000 psi (0 to 200 bar)
- Burst Rating6:3x
- Hi Side Media2:316 SS
- Lo Side Media2:N/A
- Reference Uncertainty4:± 0.0175%
- Total Uncertainty 1-year (15-35°C):± 0.035%
- Total Uncertainty 1-year1:± 0.045%
- Total Uncertainty 6-month (15-35°C):± 0.03%
- Total Uncertainty 6-month1:± 0.04%
Applications
- Pressure instrument calibration
- Petro-Chemical
- Oil and Gas
- Pharmaceutical
- Water and wastewater
- Food and Beverage
- Power Generation
Fluke 750P29EX Pressure Module, 3000 PSIG, WET
Features
- Digital communication eliminates errors due to poor connections and electrical interference
- The modules are inherently temperature compensated from 0 to 50°C (32 to 122°F)
- The modules are fully interchangeable because all measurements are completed in the pressure module itself and then communicated to the calibrator in digitized form
- Modules are calibrated independently of the calibrator, and can be used with any 718Ex or 725Ex calibrator
- Each module has its own serial number to maintain independent traceability
- Rugged construction, urethane over molding protects against shock if dropped and seals against dirt, dust, and moisture ingress
- Pressure connections are ⅛” NPT female, easily converted using adapter set
- ¼” NPT Male, ¼” BSP/ISO and M20 male adapters are provided with each pressure module
- Convenient setup, one-meter cable between the pressure module and calibrator reduces the length of connecting tubing to the pressure source
- Three-year warranty, best in class compared to competitors one year warranty
- Added IEC-Ex certification for compliance in extended geographies
Comparing pressure module specifications, it is important to compare both the temperature range the time period the specifications apply. Matching the pressure range to the application is critical for best performance in performing a calibration.
Applications
- Instrument Maintenance
- Control Systems
- Safety Systems
- Process and Environmental Monitors
Fluke 750P30 High Pressure Module, 0-340 Bar, 3X Burst Rating
Features
- Parameter/Range:0 to 5000 psi (0 to 340 bar)
- Burst Rating6:3x
- Hi Side Media2:316 SS
- Lo Side Media2:N/A
- Reference Uncertainty4:± 0.0175%
- Total Uncertainty 1-year (15-35°C):± 0.035%
- Total Uncertainty 1-year1:± 0.045%
- Total Uncertainty 6-month (15-35°C):± 0.03%
- Total Uncertainty 6-month1:± 0.04%
Applications
- Pressure instrument calibration
- Petro-Chemical
- Oil and Gas
- Pharmaceutical
- Water and wastewater
- Food and Beverage
- Power Generation