Fluke 9144 – High Temperature Field Drywell
Key features
- Lightweight, portable, and fast
- Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current
- True reference thermometry with accuracy to ±0.01 °C
- On-board automation and documentation
- Metrology performance in accuracy, stability, uniformity, and loading
Fluke 9144-INSA Dry Block Insert A for the Fluke 9144
What’s included with the Fluke 9144-INSA
- Fluke 9144-INSA Dry Block Insert A for the Fluke 9144
Fluke 9144-INSB Dry Block Insert B for the Fluke 9144
What’s included with the Fluke 9144-INSB
- Fluke 9144-INSB Dry Block Insert B for the Fluke 9144
Fluke 9144-INSC Dry Block Insert C for the Fluke 9144
What’s included with the Fluke 9144-INSC
- Fluke 9144-INSC Dry Block Insert C for the Fluke 9144
Fluke 9144-INSD Dry Block Insert D for the Fluke 9144
What’s included with the Fluke 9144-INSD
- Fluke 9144-INSD Dry Block Insert D for the Fluke 9144
Fluke 9144-INST Blank Dry Block Insert for the Fluke 9144
What’s included with the Fluke 9144-INST
- Fluke 9144-INST Blank Dry Block Insert for the Fluke 9144
Fluke 9150 Thermocouple Furnace
-
- Temperature range to 2192°F (1200°C) with a stability of ±0.5°C, and display accuracy of ±5°C across its entire range
- Uses Hart’s microprocessor-based controller for great stability and set-point accuracy
- Rapid cool-down and heat-up times
- Interchangeable multiple hole probe sleeves
- Eight set-point memory
- Adjustable readout in °C or °F
- RS-232 port for connection to a PC
Fluke 9170, 9171, 9172, & 9173 Metrology Well Calibrators
- Best-performing industrial heat sources (accuracy, stability, uniformity) in the world
- Immersion depth to 203 mm (8 in)
- Optional ITS-90 reference input reads PRTs to ±0.006 °C
- Temperature range from –45 °C to 700 °C
Fluke 9190A Ultra-Cool Field Metrology Well
Wide temperature range
–95 °C to 140 °C
Excellent accuracy
Accuracy using built-in reference thermometer readout: ± 0.05 °C full range
Display accuracy: ± 0.2 °C full range
Best-in-class stability
± 0.015 °C full range
Fast cooling time
23 °C to –90 °C: 80 minutes
23 °C to –95 °C: 90 minutes
140 °C to 23 °C: 60 minutes
Fluke 9210 Mini Triple Point of Water Maintenance Apparatus
- Easy preprogrammed realization
- Inexpensive fixed-point solution
- Training takes a few hours
Fluke 922 Airflow Meter/Micromanometer
- Measure pressure drops across key HVAC equipment to drive peak performance and extend equipment life
- Match ventilation to occupant loads
- Monitor indoor vs. outdoor pressure relationships and manage the building envelope
- Promote indoor comfort and quality
- Perform duct traversals for accurate airflow readings
Fluke 922/KIT Airflow Meter/Micromanometer
You can use the Fluke 922 to:
- Measure pressure drops across key HVAC equipment to drive peak performance and extend equipment life
- Match ventilation to occupant loads
- Monitor indoor vs. outdoor pressure relationships and manage the building envelope
- Promote indoor comfort and quality
- Perform duct traversals for accurate airflow readings