Fluke 3130 Portable Pressure Calibrator
- Measure and generate pressures from vacuum to 2 MPa (300 psi, 20 bar)
- Internal pump can generate vacuum to -80 kPa (-12 psi, -0.8 bar) or pressure to 2 MPa (300 psi, 20 bar)
- Supply pressure connection allowing the use of external gas supply up to 2 MPa (300 psi, 20 bar)
- Includes variable volume for fine adjustment of pressures
- Pressure measurement accuracy of ± (0.025 % reading + 0.01 % FS)
- Electrical measurement and 24 volt supply for close looped calibrations
- Measure or generate 4 to 20 mA
- Measure 0 to 30 V dc
- Powered by internal, high capacity, NiMH battery or universal ac mains adapter
- Compatible with Fluke 700P and 750P Pressure Modules
Fluke 3990 Manual Pressure Control Packs
- Self-contained for ease-of-use
- Includes precision adjustor to allow increments as fine as 0.00025 psi
- 1000 and 3000 psi models also provide absolute and negative gauge mode
- Includes metering valve for fine control
- Vent valve provides easy means to vent pressure to atmosphere
- Convenient 1/4 inch NPT connections
Fluke 5606 Full Immersion PRT
- 5606: -200 °C to 160 °C
- Calibration accuracy of ± 0.05 °C
- Transition junction and lead wires can withstand full PRT temperature range
- Unique probe seal of 5606 prevents ingress of moisture
- NVLAP-accredited calibration
Fluke 5610, 5611, 5611T, 5665 Temperature Probes, Reference Thermistor Probes
- Temperature probes with short-term accuracy to ± 0.01 °C; one-year drift < ± 0.01 °C
- Accredited NVLAP calibration optional
- Flexible PTFE and silicone coated fast-response models
- Rugged polished stainless steel sheaths
Fluke 5615 Secondary Reference Temperature Standards
- Affordable wide-range accuracy
- Calibrated accuracy ± 0.012 °C at 0 °C
- Reference-grade platinum sensing element
- NVLAP-accredited calibration included, lab code 200706-0
Fluke 5618B Small Diameter Industrial RTD
- Small diameter sheath, 3.2mm (0.125 in)
- Excellent stability
- Includes ITS-90 coefficients
- NVLAP-accredited calibrated from –200°C to 500°C, lab code 200706-0
Fluke 5622 Fast Response Platinum Resistance Thermometers (PRTs)
- Time constants as fast as 0.4 seconds
- NVLAP-accredited calibration, lab code 200348-0
- Small probe diameters ranging from 0.5 mm to 3.2 mm
Fluke 5623B Precision RTD Freezer Probe
- Fully immersible probe assembly to –100°C
- NVLAP-accredited calibration, lab code 200706-0, and ITS-90 coefficients included
- Accuracy to ±0.05°C over the full range
Fluke 5624 Platinum Resistance Thermometer to 1000 °C
- Temperature range of 0°C to 1000°C
- Accuracy (includes short-term stability and calibration uncertainty) of ±0.05°C to 962°C
- Long-term drift of 0.01°C at 0°C after 100 hours at 1000°C
- Designed by Fluke Calibration’s primary standards design team
Fluke 5626, 5628 Secondary Standard PRTs
- Range to 661°C
- Meets all ITS-90 requirements for resistance ratios
- Rtp drift < 20 mK after 500 hours at 661°C
- Calibrated accuracy of ± 0.006 °C at 0 °C
Fluke 5627A Precision Thermometer, RTD Temperature Probe
- Vibration and shock resistant
- NVLAP-accredited calibration included, lab code 200706-0
Fluke 5640 Series Thermistor Standards Probes
- Accuracy to ± 0.001 °C
- Affordable system accuracy to ± 0.004 °C or better
- NIST-traceable calibration included from manufacturer; accredited calibration from Fluke Calibration optional