Fluke 52120A Transconductance Amplifier
52120A performance at a glance
- Industry-leading amplifier accuracy:
- – 140 ppm ac (used with 61XXA Electrical Power Standard or 5730A)
- – 350 ppm ac (used with dc/lf calibrator
- – 160 ppm dc (used with dc/lf calibrator
- Frequency: DC to 10 kHz
- Burden voltage (compliance): 4.5 V @ 120 A
- Inductive drive capability: 1 mH load
- Output ranges: 2 A, 20 A, 120 A
- Input ranges: 2 V or 200 mA F.S. for 2 A and 20 A ranges, 1.2 V or 120 mA F.S. for 120 A range
- Parallel operation: (Closed loop mode with 61XXX or 5730A) 2 or 3 amplifiers, up to 360 A in a single phase
- Parallel operation: (Standalone mode), up to 10 amplifiers, up to 1200 A in a single phase
- Accessory coils: 25-turn coil supports 3000 A, 50-turn coil supports 6000 A
- Control communication with 6105A/6100B Electrical Power Standards or 5730A
- GPIB remote operation
Fluke 5322A Electrical Safety Tester Calibrator
The 5322A calibrates a broad range of equipment, including:
- Hipot testers
- Insulation resistance testers (megohm-meters) including older analog testers
- Loop/line impedance testers
- Continuity testers
- Earth resistance testers
- Ground bond testers
- Leakage current testers
- Circuit breaker testers (RCD/GFCI)
- Multifunction installation testers
- Portable appliance testers (PATs)
Fluke 5502A Multi-Product Calibrator
- Handheld and bench meters (analog and digital) to 4.5 digits
- Current clamps and clamp meters
- Panel meters
- Electronic thermometers
- Chart recorders
- Oscilloscope recorders
- XY recorders
- Data loggers
Fluke 5522A Multi-Product Calibrator
- Calibrates a wide variety of electrical test equipment
- Robust protection circuits prevent costly damage from operator error
- Resistance calibrator, voltage calibrator, current calibrator and more
- Redesigned carrying handles make the 5522A easy to transport
- Rugged optional carrying case with built-in handles and wheels and removable front/rear access doors for in-situ calibration in almost any environment
- Remarkably affordable
Fluke 5725A Amplifier
- Frequency limits at higher voltage increase to 100 kHz at 750 V, 30 kHz at 1100 V
- Load limits are to 70 mA for frequencies above 5 kHz, and to 50 mA for frequencies less than 5 kHz
- Capacitive load limits are increased to 1000 pF
Fluke 5730A High Performance Multifunction Calibrator
- Improved performance specifications for ac voltage, ac current and resistance
- 6.5 inch VGA capacitive touch screen with full color graphical user interface
- Visual Connection Management™ output terminals guide connections
- Graphical user interface in nine languages
- Compatible with 52120A and 5725A amplifiers
- Full MET/CAL® compatibility with 5700A and 5720A procedures
- Artifact Calibration using 10 V, 1 Ω and 10 kΩ external standards; 30 MHz and 50 MHz wideband output options available
Fluke 6105A, 6100B Electrical Power Quality Calibrator
Wide workload coverage
The 6105A and 6100B cover a wide workload of electrical power test instruments, including:
- AC voltmeters
- AC ammeters
- Current transformers
- Flicker meters
- Phase angle meters
- Power factor meters
- Power analyzers
- Power recorders
- Power transducers-relay testers
- VA meters
- VAR meters
- Voltage transformers
- Wattmeters (3- or 4-wire)
- Watthour meters
- and more
Fluke 6135A/PMUCAL Phasor Measurement Unit Calibration System
The 6135A/PMUCAL system enables you to:
- Calibrate and test a PMU from a client PC, either at the site of the test system or remotely over the Internet
- Quickly set up a PMU test
- Speed through automated calibration procedures or interactively do custom PMU testing
- Provide the required static and dynamic voltage and current conditions that occur in a power distribution grid specified by the standard
- Apply those signals to a phasor measurement unit
- Capture the PMU’s reported results
- Evaluate the total vector error (TVE), frequency error (FE), and rate of change of frequency error (RFE)
- Compare those results with the original stimulus
- Evaluate against the thresholds defined in IEEE Std C37.118.1a™-2014
- Create test reports, graphs and calibration certificates that can be readily printed or shared electronically
Fluke 7526A Precision Process Calibrator
- Sources and measures dc voltage, current, resistance, RTDs and thermocouples
- Extend pressure measurement range with any Fluke 750P and 700P Series Pressure Modules
- Includes 24 V dc transmitter loop power supply
- Measures 4-20 mA loop current
- Includes automated switch-test function
- Accepts ITS-90 coefficients for accurate SPRT measurements
- Compatible with MET/CAL® Calibration Software
- Includes certificate of calibration traceable to national standards (optional A2LA accredited calibration available upon request)
Fluke 9500B Oscilloscope Calibrator
- Full automation provides totally hands-free oscilloscope calibration – even on today’s ultra-high performance, multi-channel, feature rich instruments.
- Continuous upgradeability helps you protect your investment in the tools you need to manage ever changing workload demands.
- Simultaneous output on 5 channels means no more lead changing and no more complicated signal multiplexers or impedance matching networks.
- Leveled sinewaves to 6.0 GHz and edges to 70 ps provide all the performance and flexibility you need to fully calibrate today’s and tomorrow’s high performance oscilloscopes.
- Fluke Calibration’s unique Active Head Technology™ generates calibration signals right at the oscilloscope input – now there is no doubt whether waveform aberrations are down to connecting leads or the oscilloscope itself.
Fluke 8558A 8.5 Digit Multimeter
- Voltage sensitivity to hundreds of nV and current sensitivity to hundreds of pA allows you uncover ultra-low level transient signals
- Up to 20 MHz bandwidth for voltage and 4 MHz for current retains high bandwidth content of the signal measured
- 18-bit SAR analog-to-digital converter that achieves 5 mega-samples per second
- 5 mega-samples per second sample rate, into buffer, for capturing complex, fast changing waveforms
- 15 million readings memory allows large amount of data storage eliminating the
- immediate need to transfer data to a PC
- Graphical waveform display enables real-time visualization of complex waveforms, increased productivity with faster access to results and answers
Fluke 8588A Reference Multimeter
- 2.7 µV/V (95%), 3.5 µV/V (99%), 1 year relative accuracy, dc voltage without internal self-calibration or auto-adjustments
- 0.5 µV/V (95%), 0.65 µV/V (99%), 24 hour stability, dc voltage
- 7 µΩ/Ω (95%), 9 µΩ/Ω (99%), 1 year, resistance
- 2.02x full scale stretches lower noise floor to higher signal levels to maximize higher accuracies from the instrument
- 200 ns to 100 s aperture setting allows the industry’s widest flexibility to control data capture window