Fluke 5698-25 Working Standard SPRT

  • Conforms to ITS-90 SPRT guidelines
  • Drift rate typically 0.003 °C
  • Calibration options by fixed point
  • Unmatched performance-to-price-ratio
Read more
Close

Fluke 5699 High-Temperature Metal-Sheath SPRT

  • Range to aluminum point (660 °C )
  • Inconel™ and platinum sheaths guard against contamination
  • Less than 8 mK/year drift
  • Many calibration options available including by fixed point
  • Fifth wire provides shield ground
Read more
Close

Fluke 7312 Triple Point of Water Maintenance Bath

  • Maintains TPW cells for up to six weeks
  • Optional immersion freezer for simple cell freezing
  • Independent cutout circuit protects cells from breaking
Read more
Close

Fluke 9114, 9115A, 9116A Freeze-point furnaces

  • Designed to extend plateaus
  • High-stability OEM controllers, RS-232 included
  • External cooling coils
Read more
Close

Fluke 9117 Annealing Furnace

  • Guards against contamination
  • Anneals both SPRTs and HTPRTs
  • Fully programmable
Read more
Close

Fluke 9210 Mini Triple Point of Water Maintenance Apparatus

  • Easy preprogrammed realization
  • Inexpensive fixed-point solution
  • Training takes a few hours
Read more
Close

Fluke 9230 Gallium Cell Maintenance Apparatus

  • One week plateau duration
  • No hassle automatic realizations
  • Used daily in our Primary Lab
Read more
Close

Fluke 9260 Mini Fixed-Point Cell Furnace

  • Good introduction to fixed-point calibration
  • User friendly and inexpensive
Read more
Close

Fluke 7196B LN₂ Comparison Calibrator

  • Low-cost calibrations to –196°C
  • Simple to use
  • Uncertainty less than 2 mK
Read more
Close

Fluke 1594A, 1595A Super-Thermometers

  • Calibrate SPRTs, PRTs, RTDs and thermistors (0 Ω to 500 k Ω)
  • Accuracy as good as 0.06 ppm (0.000015 °C)
  • “Ratio Self-Calibration” verifies and calibrates resistance ratio accuracy
  • Automatic zero-power measurements calculate thermometer probe self-heating
  • Temperature-controlled internal reference resistors
  • Calibrated sensing current lowers overall instrument uncertainty
  • Four input channels on the front panel accept sensors under test or external references
  • Two dedicated external reference input channels on the rear panel
  • Standby current reduces transient effects when scanning between channels
  • Channel Select keys turn measurement mode on or off at the touch of a button
  • Sample rates as fast as one second
  • USB data transfer and computer control
  • Remote view and device control via Ethernet
  • Compatible with MET/TEMP II automated calibration software and LogWare II multichannel, real-time data acquisition software
Read more
Placeholder
Close

Fluke 5430 Standard AC/DC Resistors

  • Long-term stability better than 2 ppm/year (< 1 ppm typical)
  • Traceable AC and DC calibrations available
  • National lab design proven for more than 25 years
Read more
Close

Fluke 742A Resistance Standards

  • Small and rugged resistance calibrators
  • No oil or air baths required
  • 18° to 28° C operating range
  • Six-month stability to 2.5 ppm
  • Supplied with temperature characterization
Read more