Fluke 2271A Industrial Pressure Calibrator
- Calibrate a wide range of gauges and sensors with a single instrument
- Two levels of accuracy, 0.01% reading or 0.02% FS
- Wide measurement range from -100 kPa to 20 MPa (-15 to 3000 psi)
- Removable pressure measurement modules make it easy to change or add measurement ranges
- Integrated electrical measurement module with HART communication provides a complete solution for calibrating pressure transmitters
- Built-in dual test ports enable you to connect multiple devices under test (DUTs)
- Localized graphical user interface in choice of ten languages
Fluke 2456 Piston Gauge Monitor
- Automates piston gauge calibrations
- Monitors critical piston gauge parameters
- Dual channel capability for cross float calibrations
- WinPrompt software is Windows based
- Use WinPrompt alone or in combination with Model 2456 PGM
- Export data to create customized calibration reports and certificates
Fluke 2456-LEM Laboratory Environment Monitor
- Communicates via RS-232 or RS-485
- Includes software to display all parameters in addition to data logging and calibration
- Precision to 0.1 °C, 0.04 inHg (1.3 mbar) and 3 % RH
- Ideal for calibration labs, clean rooms, storage facilities or use with Ruska piston gauges
- Replaces mechanical strip chart recorders
Fluke 2465A Gas Piston Gauge
- Pressure ranges from 1.4 kPa to 7 MPa (0.2 to 1000 psi)
- Accuracy to 0.0010% (10 ppm) of reading for pressures to 700 kPa (100 psi)
- Accuracy to 0.0027% (27 ppm) of reading for pressures
greater than 700 kPa to 7 MPa (100 psi to 1000 psi) - Precision better than 3 ppm
- Stability better than 3 ppm per year
- Resolution 0.0001% (1 ppm) or 1 mg
- Gauge, absolute, vacuum and low pressure modes
Fluke 2468A – Pitot/Static Primary Standard
- Pressure range: 0.4 to 103 inHg
- Optional range: 3.4 to 400 inHg
- Accuracy to ±0.5 feet, 0.003 knots
- Ideal for calibrating RVSM compliant test sets
- Absolute and gauge calibration for Ps, Pt & Qc ranges
- Calibrate in a variety of units
Fluke 2638A Hydra Series III Data Acquisition System/Digital Multimeter
- DC accuracy of 0.0024 %
- Thermocouple accuracy of 0.5 °C
- Up to 66 universal differential isolated inputs
- On-screen color trend graphing of up to four channels at a time
- Easy-to-use menu system for setup and data management
- Input types: ac V, dc V, ac I, dc I, thermocouple, PRT (2, 3, 4 w), thermistor, resistance (2-4 w), frequency
- Multi-channel real-time data display
- 6.5-digit bench DMM function for front-panel inputs
- Monitor function for real-time viewing and charting between scans
- 20 on-board math channels
- One-button screen capture of chart or data displays
- 45 channels/second basic dc scan rate
- Internal 57,000 scan/setup file memory
- USB flash drive support
- Data security features
- 300 V CAT II input safety rated
- Supported by TQSoft and TQAero thermal validation software for FDA 21 CFR Part 11 and AMS 2750 compliant data collection
Fluke 2680 Series Data Acquisition Systems
- 20 to 120 universal analog inputs per chassis; systems to +2,000 channels
- Stand-alone data logger operation with the 2686A
- Large scalable LAN systems using the 2680A with 10BaseT/100BaseT
- Two types of Universal Input Modules: high-isolation precision modules or fast scan modules, with 16- to 18-bit resolution
- Throughput of more than 3,000 channels-per-second-per-chassis with 2680A-FAI modules
- Superior thermocouple measurement accuracy (J, K, R, S, T, N, I, U, C, B)
- 20 digital I/O and 8 form C, 1 Amp relay output modules for direct control of equipment
- Up to 300V input isolation, 1600V transient overvoltage protection (2680A-PAI)
- Universal input conditioning for any input, on any channel, in any combination (V dc, V ac, Ohms, frequency, RTD, thermocouple, thermistor or current
- ATA flash memory card for stand-slone operation – from 16 MB to 1 GB (2686A only)
- Multiple power sources: 100 to 240 V and 9 V to 45 V dc
- Includes Fluke DAQ Software » which: Controls all 2680 Series functions, provides real-time and historical and also communicates with and 2645A NetDAQ » products
Fluke 2700G Series Reference Pressure Gauges
- Precision pressure measurement from 100 kPa (15 psi, 1 bar) to 70 MPa (10 000 psi, 700 bar)
- Accuracy to 0.02% of full scale
- Easy-to-use, rugged construction for reliable performance
- Combine with the 700PTPK or 700HTPK pump kits for a complete portable pressure testing solution for up to 600 psi with the PTP-1 pneumatic pump and up to 10 000 psi with the HTP-2 hydraulic pump
- Combine with the P5510, P5513, P5514, or P5515 Comparison Test Pumps for a complete bench top pressure calibration solution
- Test port is 1/4 NPT Male. 1/4 BSP and M20 X 1.5 adaptors are included standard
- USB communications cable and universal power supply provided standard
- Can be used with COMPASS® for Pressure software for automated recording of pressure calibration data
Fluke 3130 Portable Pressure Calibrator
- Measure and generate pressures from vacuum to 2 MPa (300 psi, 20 bar)
- Internal pump can generate vacuum to -80 kPa (-12 psi, -0.8 bar) or pressure to 2 MPa (300 psi, 20 bar)
- Supply pressure connection allowing the use of external gas supply up to 2 MPa (300 psi, 20 bar)
- Includes variable volume for fine adjustment of pressures
- Pressure measurement accuracy of ± (0.025 % reading + 0.01 % FS)
- Electrical measurement and 24 volt supply for close looped calibrations
- Measure or generate 4 to 20 mA
- Measure 0 to 30 V dc
- Powered by internal, high capacity, NiMH battery or universal ac mains adapter
- Compatible with Fluke 700P and 750P Pressure Modules
Fluke 3990 Manual Pressure Control Packs
- Self-contained for ease-of-use
- Includes precision adjustor to allow increments as fine as 0.00025 psi
- 1000 and 3000 psi models also provide absolute and negative gauge mode
- Includes metering valve for fine control
- Vent valve provides easy means to vent pressure to atmosphere
- Convenient 1/4 inch NPT connections
Fluke 4180-256 – Precision IR Calibrators IR Calibrator
- Calibrated radiometrically for meaningful, consistent results.
- Accredited calibration included
- Accurate, reliable performance from –15 °C to 500 °C
- Large target size of 152 mm (6 in) is required for calibrating most thermometers.
- Light instrument weight of 8.6 kg (19 lbs) makes it easy to lift and carry.
- Intuitive, easy-to-read display that indicates when temperature is stable.
Fluke 4180-PURGEBOX Purge-Box Plexiglas for 4180 Models
What’s included with the Fluke 4180-PURGEBOX
- Fluke 4180-PURGEBOX Purge-Box Plexiglas for 4180 Models