Showing 25–48 of 338 results

Show sidebar
Close

Fluke 5080A High Compliance Multi-Product Calibrator

Calibration solutions for your analog and digital workload

  • High compliance
  • Protection circuitry
  • Calibrates a wide workload, including analog meters and 3.5 and 4.5 digits DMMs

The 5080A Multi-Product Calibrator calibrates your analog and digital workload accurately and economically. Its high voltage and current compliance makes analog workload calibration easy and precise. And built-in protection circuitry protects it against damaging input voltages.

This easy-to-use multifunction calibrator can handle a wide meter calibration workload that includes:

  • Analog meters
  • Panel meters
  • Digital multimeters
  • Watt meters
  • Clamp meters (with coil accessory)
  • Megohm meters (optional)
  • Oscilloscopes to 200 MHz (optional)
  • …and more

Versatile software applications enable you to record paperless results, and more. Best of all, the 5080A Multi-Product Calibrator offers this versatile functionality at a price that fits nicely into your budget.

Close

Fluke 5128A RHapid-Cal® Humidity Generator

  • Best-in-class system accuracy for dependable humidity probe calibration
  • Rapid humidity and temperature stabilization time for high calibration throughput
  • Supports on-site, multi-point calibration of humidity probes
  • Versatile design accommodates a large workload
  • Compact size and lightweight for easy transport
  • ISO 17025 accredited system calibration included standard
  • Easy to maintain
Close

Fluke 52120A Transconductance Amplifier

52120A performance at a glance

  • Industry-leading amplifier accuracy:
  • – 140 ppm ac (used with 61XXA Electrical Power Standard or 5730A)
  • – 350 ppm ac (used with dc/lf calibrator
  • – 160 ppm dc (used with dc/lf calibrator
  • Frequency: DC to 10 kHz
  • Burden voltage (compliance): 4.5 V @ 120 A
  • Inductive drive capability: 1 mH load
  • Output ranges: 2 A, 20 A, 120 A
  • Input ranges: 2 V or 200 mA F.S. for 2 A and 20 A ranges, 1.2 V or 120 mA F.S. for 120 A range
  • Parallel operation: (Closed loop mode with 61XXX or 5730A) 2 or 3 amplifiers, up to 360 A in a single phase
  • Parallel operation: (Standalone mode), up to 10 amplifiers, up to 1200 A in a single phase
  • Accessory coils: 25-turn coil supports 3000 A, 50-turn coil supports 6000 A
  • Control communication with 6105A/6100B Electrical Power Standards or 5730A
  • GPIB remote operation
Close

Fluke 525B Temperature/Pressure Calibrator

  • Simulates and measures all ANSI thermocouples, as well as L and U types, and provides cold junction compensation to enable calibration of a wide variety of thermocouple instrumentation.
  • Direct input for storage of ITS-90 RTD constants.
  • RTD source uncertainties to 0.03° C
  • Extend pressure measurement range with any Fluke 750P and 700P Series Pressure Modules
  • Converts easily to any pressure unit directly from the front panel or through remote communications.
  • Sources dc voltage and current for multifunction workload coverage, enabling calibration of data loggers, strip chart recorders, multimeters, and other industrial instruments.
  • Supports automation using MET/CAL® Plus Calibration Management Software or custom automated programs with standard RS-232-C and GPIB interface.
  • Eight user programmable setpoints allow quick recall of values for Zero, Span and linearity checks during calibration. Programmable setpoint dwell times for automated calibration and troubleshooting.
  • Programmable setpoint dwell times for automated calibration and troubleshooting.
  • Selectable internal or external CJC (cold junction compensation) provides you with the ability to make exacting thermocouple measurements using remote junctions.
  • Easy five-way binding posts for low-loss convenient hookup. Banana plug, screw terminal, spade lug, wraparound terminal, wire pass-through terminal.
  • NIST-traceable calibration with data is included
Close

Fluke 5322A Electrical Safety Tester Calibrator

The 5322A calibrates a broad range of equipment, including:

  • Hipot testers
  • Insulation resistance testers (megohm-meters) including older analog testers
  • Loop/line impedance testers
  • Continuity testers
  • Earth resistance testers
  • Ground bond testers
  • Leakage current testers
  • Circuit breaker testers (RCD/GFCI)
  • Multifunction installation testers
  • Portable appliance testers (PATs)
Placeholder
Close

Fluke 5430 Standard AC/DC Resistors

  • Long-term stability better than 2 ppm/year (< 1 ppm typical)
  • Traceable AC and DC calibrations available
  • National lab design proven for more than 25 years
Close

Fluke 5502A Multi-Product Calibrator

Key Features :

  • Calibrates a wide variety of electrical test equipment
  • Robust protection circuits prevent costly damage from operator error
  • Ergonomically designed carrying handles make the 5502A easy to transport
  • Rugged carrying case with built-in handles and wheels and removable front/rear access doors for in-situ calibration in almost any environment
  • Current output that extends to 120 A when paired with the 52120A Transconductance Amplifier
  • Remarkably affordable
Close

Fluke 5502A Multi-Product Calibrator

  • Handheld and bench meters (analog and digital) to 4.5 digits
  • Current clamps and clamp meters
  • Panel meters
  • Electronic thermometers
  • Chart recorders
  • Oscilloscope recorders
  • XY recorders
  • Data loggers
Close

Fluke 5522A Multi-Product Calibrator

  • Calibrates a wide variety of electrical test equipment
  • Robust protection circuits prevent costly damage from operator error
  • Resistance calibrator, voltage calibrator, current calibrator and more
  • Redesigned carrying handles make the 5522A easy to transport
  • Rugged optional carrying case with built-in handles and wheels and removable front/rear access doors for in-situ calibration in almost any environment
  • Remarkably affordable
Close

Fluke 5606 Full Immersion PRT

  • 5606: -200 °C to 160 °C
  • Calibration accuracy of ± 0.05 °C
  • Transition junction and lead wires can withstand full PRT temperature range
  • Unique probe seal of 5606 prevents ingress of moisture
  • NVLAP-accredited calibration
Close

Fluke 5610, 5611, 5611T, 5665 Temperature Probes, Reference Thermistor Probes

  • Temperature probes with short-term accuracy to ± 0.01 °C; one-year drift < ± 0.01 °C
  • Accredited NVLAP calibration optional
  • Flexible PTFE and silicone coated fast-response models
  • Rugged polished stainless steel sheaths
Close

Fluke 5615 Secondary Reference Temperature Standards

  • Affordable wide-range accuracy
  • Calibrated accuracy ± 0.012 °C at 0 °C
  • Reference-grade platinum sensing element
  • NVLAP-accredited calibration included, lab code 200706-0
Close

Fluke 5618B Small Diameter Industrial RTD

  • Small diameter sheath, 3.2mm (0.125 in)
  • Excellent stability
  • Includes ITS-90 coefficients
  • NVLAP-accredited calibrated from –200°C to 500°C, lab code 200706-0
Placeholder
Close

Fluke 5622 Fast Response Platinum Resistance Thermometers (PRTs)

  • Time constants as fast as 0.4 seconds
  • NVLAP-accredited calibration, lab code 200348-0
  • Small probe diameters ranging from 0.5 mm to 3.2 mm
Placeholder
Close

Fluke 5623B Precision RTD Freezer Probe

  • Fully immersible probe assembly to –100°C
  • NVLAP-accredited calibration, lab code 200706-0, and ITS-90 coefficients included
  • Accuracy to ±0.05°C over the full range
Close

Fluke 5624 Platinum Resistance Thermometer to 1000 °C

  • Temperature range of 0°C to 1000°C
  • Accuracy (includes short-term stability and calibration uncertainty) of ±0.05°C to 962°C
  • Long-term drift of 0.01°C at 0°C after 100 hours at 1000°C
  • Designed by Fluke Calibration’s primary standards design team
Close

Fluke 5626, 5628 Secondary Standard PRTs

  • Range to 661°C
  • Meets all ITS-90 requirements for resistance ratios
  • Rtp drift < 20 mK after 500 hours at 661°C
  • Calibrated accuracy of ± 0.006 °C at 0 °C
Close

Fluke 5627A Precision Thermometer, RTD Temperature Probe

  • Vibration and shock resistant
  • NVLAP-accredited calibration included, lab code 200706-0
Close

Fluke 5640 Series Thermistor Standards Probes

  • Accuracy to ± 0.001 °C
  • Affordable system accuracy to ± 0.004 °C or better
  • NIST-traceable calibration included from manufacturer; accredited calibration from Fluke Calibration optional
Close

Fluke 5681, 5683, 5684, and 5685 Quartz-Sheath SPRTs

  • Drift rates as low as 0.0005 K
  • Proprietary gas mixture ensures high stability
  • Most experienced SPRT design team in the business
Close

Fluke 5686-B Glass Capsule SPRT

  • Temperatures from –260 °C (13 K) to 232 °C
  • Stability typically 0.001 °C over 100 °C range
  • Miniature capsule package eliminates stem conduction
Close

Fluke 5698-25 Working Standard SPRT

  • Conforms to ITS-90 SPRT guidelines
  • Drift rate typically 0.003 °C
  • Calibration options by fixed point
  • Unmatched performance-to-price-ratio
Close

Fluke 5699 High-Temperature Metal-Sheath SPRT

  • Range to aluminum point (660 °C )
  • Inconel™ and platinum sheaths guard against contamination
  • Less than 8 mK/year drift
  • Many calibration options available including by fixed point
  • Fifth wire provides shield ground
Close

Fluke 5725A Amplifier

  • Frequency limits at higher voltage increase to 100 kHz at 750 V, 30 kHz at 1100 V
  • Load limits are to 70 mA for frequencies above 5 kHz, and to 50 mA for frequencies less than 5 kHz
  • Capacitive load limits are increased to 1000 pF