Fluke 80AK-A Thermocouple Adapter
-
Product Features:
- Adapts K-Type thermocouple mini-connector-to-dual shrouded banana plug inputs
- Measurement range and accuracy: probe dependent
- Suitable for low voltage applications (below 30V AC, 60V DC)
Compatible with
- Fluke 179 IMSK Industrial Multimeter Service Kit
- Fluke 179 True RMS Digital Multimeter
- Fluke 233 Remote Display Digital Multimeter
- Fluke 233/A Remote Display Automotive Digital Multimeter Kit
- Fluke 27 II Rugged Digital Multimeter
- Fluke 28 II Rugged Digital Multimeter
- Fluke 287 True RMS Electronics Logging Multimeter
- Fluke 289 True RMS Data Logging Multimeter
- Fluke 83V Average Responding Industrial Multimeter
- Fluke 28 II Ex Intrinsically Safe True RMS Digital Multimeter
Fluke 80BK-A Integrated DMM Temperature Probe
Features
- Standard shrouded banana jack
- Convenient one piece construction
Compatible with
- Fluke 179 IMSK Industrial Multimeter Service Kit
- Fluke 179 True RMS Digital Multimeter
- Fluke 287 True RMS Electronics Logging Multimeter
- Fluke 289 True RMS Data Logging Multimeter
- Fluke 28 II Ex Intrinsically Safe True RMS Digital Multimeter
Fluke 80CJ-M type J Male Mini-Connectors
-
Product Features:
- Isothermal screw terminals for J wire
- Suitable for up to 20 gauge thermocouple wire
- Color coded to industry standards (J-black)
- For use with Models 51, 52, 53, 54, 714, 714B, 724, 725 and 726
- Pack of 2
Fluke 80CK-M type K Male Mini-Connectors
-
Fluke 80CK-M Offers
For use with Fluke 80TK or Fluke 50 Series.
- Isothermal screw terminal for K wire
- Suitable for up to 20 gauge thermocouple wire
- Color-coded to industry standards (K-yellow)
- Two male mini-connectors per package
- One-year warranty
Fluke 80i-110s AC/DC Current Clamp
Features
- 10 or 100A AC/DC nominal current range
- Continuous current range
- 0.1 to 10A AC/DC (100mV/A output)
- 1 to 100A AC/DC (10mV/A output)
- ±3% of reading +50mA (100mV/A, 50mA to 10A)
- ±4% of reading +50mA (10mV/A, 50mA to 40A)
- ±12% of reading +50mA (40 to 80A)
- ±15% of reading (80 to 100A)
- Maximum non-destructive current of 140A (2kHz)
- Lowest measurable current of 0.1A
- 100kHz useable frequency
- CAT II 600V & CAT III 300V
- 1-year warranty
Fluke 80i-2010s AC/DC Current Clamp, 2000 A
An open-jaw, clamp-on current probe with a current range of 2000 A, and an accuracy of 0.8%, that is also
Fluke 80i-2010s/3PK AC/DC Current Clamp, 2000 A, 3-pack
An open-jaw, clamp-on current probe with a current range of 2000 A, and an accuracy of 0.8%, that is also
Fluke 80K-15 High Voltage Probe
Product Features:
- Voltage range: 1kV to 15kV DC or peak AC, 10kVrms AC
- Input resistance: 1000 Megohm
- Division ratio: 1000:1
- Safety rating(s): IEC 1010-2-031:1993, Type B, 10kV DC or peak AC, 10kVrms AC, Overvoltage Category I (voltages derived from limited energy transformer)
- Required meter input resistance: 10 Megohm
Fluke 80K-40 High Voltage Probe
Product Features:
- Voltage range: 1kV to 40kV DC or peak AC, 28kVrms AC
- Input resistance: 1000 Megohm
- Division ratio: 1000:1
- Safety rating(s): IEC 1010-2-031:1993, Type B, 40kV DC or peak AC, 28kVrms AC, Overvoltage Category I (voltages derived from limited energy transformer)
- Required meter input resistance: 10 Megohm
Fluke 80K-6 KV High Voltage Probe
Product Features:
- Voltage range: 0 to 6kV DC, or peak AC
- Input resistance: 75 Megohm nominal
- Division ratio: 1000:1
- Safety rating(s): CAN/CSA C22.2 No. 1010.2.031-94 and IEC 1010-2-031:1993, Type B, 6kV DC or peak AC, 4.24kVrms AC, Overvoltage CAT I (Voltage derived from limited energy transformers)
- Required meter input resistance: 10 Megohm
Fluke 80PJ-1 Type J Bead Probe
Fluke 80PJ-1 Offers
- This basic, inexpensive thermocouple offers good accuracy and fast response. (Not suitable for liquid immersion.)
- Type-J thermocouple for general purpose applications
- Measurement range: -40 to 260°C
Fluke 80PJ-9 General Purpose Probe
Fluke 80PJ-9 Offers
- J-type probe for use on surfaces and for insertion into air and non-caustic gases.
- Probe constructed with 304 stainless steel is compatible with J-type thermometers.
- Measurement range:-40°C to 260 °C
Fluke 80PJ-9 Specifications
Measurement Range F ( C ) -40 to 500F (-40 to 260C)
Accuracy (degree + or -) 1.1C at 0 to 260C
Probe Tip O.D. inches (mm) 0.375 (9.5)
Probe Tip Length inches (mm) 5.5 (140)
Cable Length inches (meters) 40 (1)
Manufacturer’s Warranty 1-year