Fluke i3000s AC Current Clamp
Features
- For measurement on power distribution systems
- Current ranges with 2% + 2A basic accuracy
- 1 to 30A (10mV/A output)
- 1 to 300A (1mV/A output)
- 1 to 3000A (0.1mV/A output)
- 4000A maximum non-destructive current
- 10Hz to 100kHz usable frequency
- 64mm maximum conductor diameter
- CAT III 600V safety rating
- 1-year warranty
Fluke i3000s Flex AC Current Clamp
Features
- AC RMS current ranges with ±1% accuracy
- 1 to 30A (100mV/A output)
- 1 to 300A (10mV/A output)
- 1 to 3000A (1mV/A output)
- 10Hz to 50kHz frequency
- 100kΩ minimum load impedance
- CAT III 600V safety rating
Fluke i3000s Flex-24 Flexible AC Current Probe, 24 inch length
- Three ranges: 30 A, 300 A & 3000 A, 1, 10 or 100 mV/A output
- Ideal for current measurement on thick and hard to reach conductors without breaking the circuit
- Maximum conductor diameter 178 mm
- CAT III 600V safety rating
Fluke i3000s Flex-36 AC Current Clamp, 36 inch length
Fluke I3000S-FLEX-36 Offers
The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas.
Features
- Three Ranges: 30A, 300A, and 3000A with 1, 10, or 100 mV/A output
- Ideal for current measurement on thick and hard to reach conductors without breaking the circuit
- Maximum conductor diameter 178 mm (7 in.)
- CAT III 600 V safety rating
Fluke i30s AC/DC Current Clamp
Features
- Usable current range
- 5mA to 30A DC
- 30mA to 20A AC RMS
- ±1% of reading ±2mA (@25°C)
- 100mV/A output sensitivity
- ±1mA resolution
- 1.4in crest factor
- >100kΩ load impedance
- 100kHz frequency
Fluke i310S AC/DC Current Clamp
- Current Ranges: 30 A and 300 A ACrms or ±45 A and 450 A DC
- Measuring Ranges: ±45 A and 450 A
- Output Sensitivity: 10 mV/A (40 A) to 1 mV/A (400 A)
- Resolution: ±50 mA (40 A) to ±100 mA (400 A)
- Load Impedance: > 10 k Ohms and 100 pF
- Frequency Range (small signal): DC to 20 kHz (- 3 dB)
- Phase Shift below 1 kHz, < 2 degrees
- Temperature Coefficient: ±0.1% of reading / ±C
- Power Supply: 9 V Alkaline
Fluke i400 AC Current Clamp
Features
- Take current readings without breaking the circuit
- 1 to 400A (1mA/A output)
- 2% + 0.06A accuracy
- 1000A maximum non-destructive current
- 5Hz to 20kHz frequency
- 32mm maximum conductor diameter
- Soft non-slippery overmold handle
- 1-year warranty
Fluke i400s AC Current Clamp
Features
- Take current readings without breaking the circuit
- 0.5 to 40A (10mV/A output)
- 2% + 0.015A accuracy
- 5 to 400A (1mV/A output)
- 2% + 0.04A accuracy
- 32mm maximum conductor diameter
- Soft non-slippery overmold handle
- 1-year warranty
Compatible with
- Fluke 114 Electrical Multimeter
- Fluke 117 Electrician’s Multimeter with Non-Contact Voltage
- Fluke 434-II and 435-II Power Quality and Energy Analyzers
- Fluke 438-II Power Quality Analyzer and Motor Analyzer
- Fluke PQ400 Electrical Measurement Window
Fluke I400S-EL-3PK Clamp-On Meters for the current transformers, 400 A, 3-pack
Features
- Determines the current moving through a section of circuit
- Easily attaches to the existing infrastructure
- Provides support for more circuits and systems
Fluke I40S-EL3X Clamp-On Current Transformer
Use for low current measurements with your Fluke Energy Loggers. Suitable for making measurements up to 40A.
Fluke i410 AC/DC Current Clamp
Features
- Battery-powered Hall-effect probe measures 1 to 400 A
- 1 mV/Amp output guarantees easy reading on your meter
- Take accurate current readings without breaking the circuit
- Maximum conductor Ø 32 mm
- CAT III 600 V safety rating
Fluke i410-KIT AC/DC Current Clamp with Carrry Case
Included with kit: Fluke i410 and a Zippered vinyl carry case with moveable divider.
- Fluke i410 Current Clamp (1-400A AC RMS, 1-400A DC Current Clamp)
- Zippered vinyl carry case with moveable divider