Fluke 9101 Zero-Point Dry-Well
- Bath-quality stability in a portable ice-point reference
- Easy re-calibration for long-term reliability
- Ready-light frees user’s time and attention
- Solid-state cooling technology
Fluke 9011 High-Accuracy Dual-Well Calibrator
- Combined range from –30 °C to 670 °C, one unit – two blocks
- Two independent temperature controllers (hot and cold side)
- Stability to ±0.02 °C
- Multi-hole wells for calibrating up to eight probes simultaneously
Fluke 9009 Industrial Dual-Block Thermometer Calibrator
- Temperatures from –15 °C to 350 °C in one unit
- Two wells in each block for simultaneous comparison calibrations
- Rugged, lightweight, water-resistant enclosure
Fluke 700HPPK Pneumatic Test Pump Kit
- Generate and adjust pneumatic pressures up to 21 MPa (3000 psi)
- Rugged, portable and stable enough to go anywhere — on any surface
- Reaches pressure in 20 seconds to full scale into a 30 cm3 volume
- Detachable pressure adjustment system for adjusting pressure, connecting reference and test devices on bench and in the field, and isolating and venting pressure
- Easily switch out reference gauges without requiring PTFE tape or tools
- 2-meter (6.5-foot) pressure line and assorted pressure fittings enable a wide variety of possible connections
- In-line filter and desiccant systems protect device from contamination from the DUT
Fluke 6531, 6532 E-DWT Electronic Deadweight Tester Kits
- No weights to load and unload, transport or send out for calibration
- Provides real-time pressure indication with no need to know and correct for local gravity or ambient temperature
- No piston-cylinder changes
- No significant sensitivity to level or vibration
- Able to set and read any pressure value exactly, no minimum increment limited by smallest available masses; perfect for applications that require setting a nominal pressure precisely on the device under test and measuring it, such as analog gauge calibration
- Operates in any unit of measure, switching easily from one unit to the next
Fluke 5640 Series Thermistor Standards Probes
- Accuracy to ± 0.001 °C
- Affordable system accuracy to ± 0.004 °C or better
- NIST-traceable calibration included from manufacturer; accredited calibration from Fluke Calibration optional
Fluke 5627A Precision Thermometer, RTD Temperature Probe
- Vibration and shock resistant
- NVLAP-accredited calibration included, lab code 200706-0
Fluke 5626, 5628 Secondary Standard PRTs
- Range to 661°C
- Meets all ITS-90 requirements for resistance ratios
- Rtp drift < 20 mK after 500 hours at 661°C
- Calibrated accuracy of ± 0.006 °C at 0 °C
Fluke 5624 Platinum Resistance Thermometer to 1000 °C
- Temperature range of 0°C to 1000°C
- Accuracy (includes short-term stability and calibration uncertainty) of ±0.05°C to 962°C
- Long-term drift of 0.01°C at 0°C after 100 hours at 1000°C
- Designed by Fluke Calibration’s primary standards design team
Fluke 5623B Precision RTD Freezer Probe
- Fully immersible probe assembly to –100°C
- NVLAP-accredited calibration, lab code 200706-0, and ITS-90 coefficients included
- Accuracy to ±0.05°C over the full range
Fluke 5622 Fast Response Platinum Resistance Thermometers (PRTs)
- Time constants as fast as 0.4 seconds
- NVLAP-accredited calibration, lab code 200348-0
- Small probe diameters ranging from 0.5 mm to 3.2 mm
Fluke 5618B Small Diameter Industrial RTD
- Small diameter sheath, 3.2mm (0.125 in)
- Excellent stability
- Includes ITS-90 coefficients
- NVLAP-accredited calibrated from –200°C to 500°C, lab code 200706-0