Fluke 9230 Gallium Cell Maintenance Apparatus

  • One week plateau duration
  • No hassle automatic realizations
  • Used daily in our Primary Lab
Read more
Close

Fluke 9210 Mini Triple Point of Water Maintenance Apparatus

  • Easy preprogrammed realization
  • Inexpensive fixed-point solution
  • Training takes a few hours
Read more
Close

Fluke 9117 Annealing Furnace

  • Guards against contamination
  • Anneals both SPRTs and HTPRTs
  • Fully programmable
Read more
Close

Fluke 9114, 9115A, 9116A Freeze-point furnaces

  • Designed to extend plateaus
  • High-stability OEM controllers, RS-232 included
  • External cooling coils
Read more
Close

Fluke 7312 Triple Point of Water Maintenance Bath

  • Maintains TPW cells for up to six weeks
  • Optional immersion freezer for simple cell freezing
  • Independent cutout circuit protects cells from breaking
Read more
Close

Fluke 5699 High-Temperature Metal-Sheath SPRT

  • Range to aluminum point (660 °C )
  • Inconel™ and platinum sheaths guard against contamination
  • Less than 8 mK/year drift
  • Many calibration options available including by fixed point
  • Fifth wire provides shield ground
Read more
Close

Fluke 5698-25 Working Standard SPRT

  • Conforms to ITS-90 SPRT guidelines
  • Drift rate typically 0.003 °C
  • Calibration options by fixed point
  • Unmatched performance-to-price-ratio
Read more
Close

Fluke 5686-B Glass Capsule SPRT

  • Temperatures from –260 °C (13 K) to 232 °C
  • Stability typically 0.001 °C over 100 °C range
  • Miniature capsule package eliminates stem conduction
Read more
Close

Fluke 5681, 5683, 5684, and 5685 Quartz-Sheath SPRTs

  • Drift rates as low as 0.0005 K
  • Proprietary gas mixture ensures high stability
  • Most experienced SPRT design team in the business
Read more
Placeholder
Close

Fluke Mini Fixed-Point Cells

  • Lower uncertainties than comparison calibrations
  • All ITS-90 fixed points from TPW to copper
  • Reduced equipment and annual recalibration costs
Read more
Close

Fluke ITS-90 Fixed-Point Cells

  • Best cell uncertainties commercially available
  • Every ITS-90 fixed point available from argon to copper
  • Plateaus last days (gallium for weeks and TPW for months)
  • Manufactured and tested by Fluke Calibration’s primary standards scientists
Read more
Placeholder
Close

Fluke 5960A Triple Point of Argon System

  • Low uncertainty of 0.25 mK
  • Temperature plateau duration longer than 30 hours
  • Four entrant wells with radial uniformity less than 0.05 mK
  • 480 mm total immersion depth
  • Argon purity of 99.9999 %
  • Multi-language display support
Read more