Fluke 1587 FC Insulation Multimeter
- Provides memory storage through Fluke Connect Measurements to eliminate the need to write down results
- Includes live circuit detection to prevent insulation test if voltage >30 V is detected
- Provides automated temperature compensation to establish accurate baselines
- Supports historical tracking and asset trending of assets to identify degradation over time with Fluke Connect® Assets (sold separately)
- Incorporates VFD low-pass filter for accurate variable frequency motor drive measurements
- Includes auto-discharge of capacitive voltage for added user protection
- Measures ac/dc voltage, dc millivolts, ac/dc milliamps, resistance, and continuity
- Includes capacitance, diode test, temperature, min/max, frequency measurements and insulation test smoothing reading
- Automatically powers off to save battery power
- Comes with remote probe, test leads, alligator clips, K-type thermocouple, hard case, and three-year warranty.
Fluke 1587 T Insulation Multimeter
Fluke 1587 T Offers
Features
- Large display with backlight
- Insulation test: 0.01 Mohm to 2 Gohm
- Insulation test voltages: 50 V, 100 V, 250 V, 500 V, 1000 V
- Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection
- Auto-discharge of capacitive voltage for added user protection
- AC/DC voltage, DC milliVolts, AC/DC milliamps, Resistance (ohm), Continuity
- Filter for motor drive measurements
- Capacitance, diode test, temperature, Min/Max, frequency (Hz)
- Auto power off to save battery power
- CAT III 1000 V, CAT IV 600 V measurement category
- Accepts optional Fluke TPAK™ magnetic hanging system to free your hands for other work
- Rugged, utility hard case allows you to bring everything you need for the job
- Three year warranty
Fluke 1587/MDT FC Advanced Motor & Drive Troubleshooting Kit
Features
- Fluke 1587 FC
- Insulation Test Voltages: 50V, 100V, 250V, 500V, 1000V
- Insulation Test: 0.01 MΩ to 2.0GΩ
- AC/DC voltage
- DC millivolts
- Insulation test smoothing reading
- Frequency measurement
- Capacitance measurement
- Diode test
- Temperature measurement
- CAT III 1000V, CAT IV 600V measurement category
- Fluke i400 Clamp Meter
- Measures up to 400A AC
- 1 – 400A continuous current range
- 2% + 0.06A basic accuracy
- 1mA / amp output
- CAT IV 600V / CAT III 1000V Safety rating
- Max. conductor 32mm diameter
- Fluke 9040 Phase Rotation Indicator
- 3 phase indication
- Indication of phase rotation
- 40-700 V voltage range
- 15-400 Hz frequency range
- Clear LCD display
- Continuous operating timer
- IP40 dust/water resistance
- CAT III 600 V overvoltage rating
- No battery required
Fluke 1587FC Insulation Multimeter
Fluke 1587 FC Offers
- PI/DAR timed ratio tests (1587 FC only)
- Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection
- VFD low-pass filter for accurate motor drive measurements (1587 FC only)
- Auto-discharge of capacitive voltage for added user protection
- Insulation test (1587 FC: 0.01 MΩ to 2 GΩ) (1577: 0.1 MΩ to 600 MΩ)
- Insulation test voltages (1587 FC: 50 V, 100 V, 250 V, 500 V, 1000 V),(1577: 500 V, 1000 V) for many applications
- AC/DC voltage, DC millivolts, AC/DC milliamps, Resistance (Ω), Continuity
- Capacitance, diode test, temperature, Min/Max, frequency (Hz)(1587 FC only)
- Auto power off to save battery power
- CAT III 1000 V, CAT IV 600 V measurement category
- Rugged, utility hard case allows you to bring everything you need for the job
- Large display with backlight
Fluke 1594A, 1595A Super-Thermometers
- Calibrate SPRTs, PRTs, RTDs and thermistors (0 Ω to 500 k Ω)
- Accuracy as good as 0.06 ppm (0.000015 °C)
- “Ratio Self-Calibration” verifies and calibrates resistance ratio accuracy
- Automatic zero-power measurements calculate thermometer probe self-heating
- Temperature-controlled internal reference resistors
- Calibrated sensing current lowers overall instrument uncertainty
- Four input channels on the front panel accept sensors under test or external references
- Two dedicated external reference input channels on the rear panel
- Standby current reduces transient effects when scanning between channels
- Channel Select keys turn measurement mode on or off at the touch of a button
- Sample rates as fast as one second
- USB data transfer and computer control
- Remote view and device control via Ethernet
- Compatible with MET/TEMP II automated calibration software and LogWare II multichannel, real-time data acquisition software
Fluke 1620A Digital Thermometer-Hygrometer
- Superior accuracy
- Network enabled
- Powerful logging and analysis tools
- Two interchangeable calibrated sensors
- Huge memory
- Upgraded software
Fluke 1623-2 Earth Ground Resistance Meter
- Adjustable stroke length can be set to limit the pressure per stroke
- 1/4 in NPT male to 1/4 in BSP female
- 1 meter of hose
- (2) 1/8 in NPT male quick connects
- 1/8 NPT female to 1/4 in BSP female
- Seal Kit
- Instruction sheet
Fluke 1623-2-KIT Basic Geo Earth Ground Tester Kit
Features
- One-button measurement concept
- 3- and 4-pole earth ground measurement
- 4-pole soil resistivity testing
- Selective testing, no disconnection of ground conductor (one clamp)
- Stakeless testing, quick ground loop testing (two clamps)
- Measuring frequency 128 Hz
Fluke 1625-2 GEO Earth Ground Tester
- Provides R* measurement that calculates earth ground impedance at 55 Hz to more accurately reflect the earth ground resistance that a fault-to earth ground would see
- Includes USB port for data storage and transfer
- Features IP56 rating for outdoor use
- Offers adjustable limits for quicker testing
- Comes with a rugged carrying case
Fluke 1625-2-KIT Advanced Geo Earth Ground Tester Kit
Features
- One-button measurement concept
- 3- and 4-pole earth ground measurement
- 4-pole soil resistivity testing
- Selective testing, no disconnection of ground conductor (1 clamp)
- Stakeless testing, quick ground loop testing (2 clamps)
- Measuring frequency 128 Hz
Fluke 1630-2 FC Earth Ground Clamp
- AC leakage current measurement – identify ac leakage currents without disconnecting the earth ground stake from the grounding system – ideal for system troubleshooting
- Rugged – heavy-duty clamp jaw stays in alignment and in calibration even in every day, on the job industrial environments
- Logging measurements – the earth ground clamp saves time by automatically recording data at pre-set intervals and saves up to 32,760 measurements in memory at the set logging interval
- Alarm threshold – user-defined high/low alarm limits, for rapid measurement evaluation
- Band-pass filter – selectable band-pass filter function removes unwanted noise from the ac leakage current measurement
- Fluke Connect compatible
Fluke 1662 – Multifunction Electrical Tester
A solid, reliable, basic installation tester
- Tests voltage and frequency
- Checks wiring polarity to detect broken N wires
- Measures insulation resistance and loop and line resistance
- Measures motor windings with continuity test
- Calculates prospective earth fault current (PEFC/IK) and prospective short-circuit current (PSC/IK)