Showing 289–300 of 338 results

Show sidebar
Close

Fluke 9230 Gallium Cell Maintenance Apparatus

  • One week plateau duration
  • No hassle automatic realizations
  • Used daily in our Primary Lab
Close

Fluke 9260 Mini Fixed-Point Cell Furnace

  • Good introduction to fixed-point calibration
  • User friendly and inexpensive
Close

Fluke 9500B Oscilloscope Calibrator

  • Full automation provides totally hands-free oscilloscope calibration – even on today’s ultra-high performance, multi-channel, feature rich instruments.
  • Continuous upgradeability helps you protect your investment in the tools you need to manage ever changing workload demands.
  • Simultaneous output on 5 channels means no more lead changing and no more complicated signal multiplexers or impedance matching networks.
  • Leveled sinewaves to 6.0 GHz and edges to 70 ps provide all the performance and flexibility you need to fully calibrate today’s and tomorrow’s high performance oscilloscopes.
  • Fluke Calibration’s unique Active Head Technology™ generates calibration signals right at the oscilloscope input – now there is no doubt whether waveform aberrations are down to connecting leads or the oscilloscope itself.
Placeholder
Close

Fluke 9600FLT 1 GHz Wide Offset Phase Noise Filter

Use the Filter only at 1 GHz. It rejects phase noise at offsets greater than 1 MHz from the 1 GHz carrier (both sidebands are rejected). Use the filter only when the phase noise specification of the 96xx RF Reference Source is not considered sufficient for the target workload. Only the highest performance spectrum analyzers are likely to require the filter. The filter connects in series with the umbilical lead of the 9640A-50 or 9640A-75 Leveling Head. Use the supplied mounting kit to conveniently attach the filter to the front left handle of the Reference Source. This mount is fully compatible with the Y9600 Rack Mount accessory.

Close

Fluke 96040A Low Phase Noise Reference Source

  • Covers a broad range of RF calibration workload
  • Reduces the number of instruments and interconnections required for your RF calibration system
  • “What you set is what you get” accurate signal delivery direct to the DUT input
  • Integrated 50 MHz frequency counter eliminates need for an additional instrument • Calibration-specific interface simplifies technician tasks
  • Simplifies uncertainty calculations by delivering known signals direct to the device under test (DUT)
  • Lowers RF system maintenance costs
  • With automation, reduces spectrum analyzer calibration times by as much as 50% over manual methods
Close

Fluke 96270A 27 GHz Low Phase Noise Reference Source

  • “Self-characterization” lets you avoid calculating correction factors for each component in the signal delivery system
  • “What you set is what you get” accurate signal delivery direct to the UUT input up to 27 GHz
  • Covers a broad range of RF calibration workload
  • Reduces the number of instruments and interconnections required for your RF calibration system
  • Integrated 300 MHz frequency counter and dual power meter readout eliminate need for additional instruments
  • Calibration-specific interface simplifies technician tasks
  • Simplifies uncertainty calculations
  • Lowers RF system maintenance costs
  • With automation, reduces spectrum analyzer calibration times by as much as 50 % over manual methods
Placeholder
Close

Fluke A40B Series Precision DC and AC Current Shunts

  • Simplifies calibration/verification of precision calibrators and current sources
  • Shunts sized for currents from 1mA to 100A
  • Usable from dc to 100 kHz
  • 14 individual dc and ac current shunts with a 1, 2, 5 sequence over 6 decades of current
  • Simple direct measurements, making ac/dc transfers unnecessary
  • Stability typically better then ± 5.0 µΩ/Ω for one year
  • Typical angular accuracy of better than ± 0.003º at 1 kHz
-10%
Close

Fluke BP7235 Ni-MH Battery Pack, 7.2V, 2500 mA-hour

$501.00
Excluding GST 10%

Fluke BP7235 Offers The Fluke BP7235 is a 7.2V 2500 mA-hour rechargeable Ni-MH battery pack. Provides typical 16-hour battery life

-10%
Close

Fluke BP7240 Battery Pack

$284.00
Excluding GST 10%

Li-Ion battery pack for the 75X Documenting Process Calibrator.

Close

Fluke Calibration 1523 Single Channel Reference Thermometer

$2,820.00
Excluding GST 10%

Features

  • Sensor types: PRTs, RTDs, thermistors, and thermocouples
  • PRT Accuracy: up to ± 0.011 °C
  • Thermocouple Accuracy: up to ± 0.24 °C
  • Precision thermistor Accuracy: ± 0.002 °C
  • Two models:
    • 1523: Single channel standard model with memory for 25 readings
    • 1524: Two channels; memory for logging 15,000 measurements
  • 0.3 second typical sample interval
  • Thermocouple types C, E, J, K, L, M, N, T, U, B, R, S
  • Statistics: maximum, minimum, average, standard deviation
Close

Fluke Calibration 1524 Dual Channel Reference Thermometer

$3,370.00
Excluding GST 10%

Features

  • Sensor types: PRTs, RTDs, thermistors, and thermocouples
  • PRT Accuracy: up to ± 0.011 °C
  • Thermocouple Accuracy: up to ± 0.24 °C
  • Precision thermistor Accuracy: ± 0.002 °C
  • Two models:
    • 1523: Single channel standard model with memory for 25 readings
    • 1524: Two channels; memory for logging 15,000 measurements
  • 0.3 second typical sample interval
  • Thermocouple types C, E, J, K, L, M, N, T, U, B, R, S
  • Statistics: maximum, minimum, average, standard deviation
Placeholder
Close

Fluke Calibration Bath Fluids

  • Thermal characteristics
  • Lifetime
  • Change in characteristics due to temperature cycling
  • Absorption of water from the air
  • Vaporization—fumes and fume hood requirements
  • Expansion due to heat
  • Contamination—mixing oils or introducing contamination with unclean probes
  • Conductivity properties
  • Effects of using fluids outside of their range—fire, explosion, polymerization
  • Effects of altitude on boiling point