Fluke 5080A High Compliance Multi-Product Calibrator
Calibration solutions for your analog and digital workload
- High compliance
- Protection circuitry
- Calibrates a wide workload, including analog meters and 3.5 and 4.5 digits DMMs
The 5080A Multi-Product Calibrator calibrates your analog and digital workload accurately and economically. Its high voltage and current compliance makes analog workload calibration easy and precise. And built-in protection circuitry protects it against damaging input voltages.
This easy-to-use multifunction calibrator can handle a wide meter calibration workload that includes:
- Analog meters
- Panel meters
- Digital multimeters
- Watt meters
- Clamp meters (with coil accessory)
- Megohm meters (optional)
- Oscilloscopes to 200 MHz (optional)
- …and more
Versatile software applications enable you to record paperless results, and more. Best of all, the 5080A Multi-Product Calibrator offers this versatile functionality at a price that fits nicely into your budget.
Fluke 5128A RHapid-Cal® Humidity Generator
- Best-in-class system accuracy for dependable humidity probe calibration
- Rapid humidity and temperature stabilization time for high calibration throughput
- Supports on-site, multi-point calibration of humidity probes
- Versatile design accommodates a large workload
- Compact size and lightweight for easy transport
- ISO 17025 accredited system calibration included standard
- Easy to maintain
Fluke 52120A Transconductance Amplifier
52120A performance at a glance
- Industry-leading amplifier accuracy:
- – 140 ppm ac (used with 61XXA Electrical Power Standard or 5730A)
- – 350 ppm ac (used with dc/lf calibrator
- – 160 ppm dc (used with dc/lf calibrator
- Frequency: DC to 10 kHz
- Burden voltage (compliance): 4.5 V @ 120 A
- Inductive drive capability: 1 mH load
- Output ranges: 2 A, 20 A, 120 A
- Input ranges: 2 V or 200 mA F.S. for 2 A and 20 A ranges, 1.2 V or 120 mA F.S. for 120 A range
- Parallel operation: (Closed loop mode with 61XXX or 5730A) 2 or 3 amplifiers, up to 360 A in a single phase
- Parallel operation: (Standalone mode), up to 10 amplifiers, up to 1200 A in a single phase
- Accessory coils: 25-turn coil supports 3000 A, 50-turn coil supports 6000 A
- Control communication with 6105A/6100B Electrical Power Standards or 5730A
- GPIB remote operation
Fluke 525B Temperature/Pressure Calibrator
- Simulates and measures all ANSI thermocouples, as well as L and U types, and provides cold junction compensation to enable calibration of a wide variety of thermocouple instrumentation.
- Direct input for storage of ITS-90 RTD constants.
- RTD source uncertainties to 0.03° C
- Extend pressure measurement range with any Fluke 750P and 700P Series Pressure Modules
- Converts easily to any pressure unit directly from the front panel or through remote communications.
- Sources dc voltage and current for multifunction workload coverage, enabling calibration of data loggers, strip chart recorders, multimeters, and other industrial instruments.
- Supports automation using MET/CAL® Plus Calibration Management Software or custom automated programs with standard RS-232-C and GPIB interface.
- Eight user programmable setpoints allow quick recall of values for Zero, Span and linearity checks during calibration. Programmable setpoint dwell times for automated calibration and troubleshooting.
- Programmable setpoint dwell times for automated calibration and troubleshooting.
- Selectable internal or external CJC (cold junction compensation) provides you with the ability to make exacting thermocouple measurements using remote junctions.
- Easy five-way binding posts for low-loss convenient hookup. Banana plug, screw terminal, spade lug, wraparound terminal, wire pass-through terminal.
- NIST-traceable calibration with data is included
Fluke 5322A Electrical Safety Tester Calibrator
The 5322A calibrates a broad range of equipment, including:
- Hipot testers
- Insulation resistance testers (megohm-meters) including older analog testers
- Loop/line impedance testers
- Continuity testers
- Earth resistance testers
- Ground bond testers
- Leakage current testers
- Circuit breaker testers (RCD/GFCI)
- Multifunction installation testers
- Portable appliance testers (PATs)
Fluke 5430 Standard AC/DC Resistors
- Long-term stability better than 2 ppm/year (< 1 ppm typical)
- Traceable AC and DC calibrations available
- National lab design proven for more than 25 years
Fluke 5502A Multi-Product Calibrator
Key Features :
- Calibrates a wide variety of electrical test equipment
- Robust protection circuits prevent costly damage from operator error
- Ergonomically designed carrying handles make the 5502A easy to transport
- Rugged carrying case with built-in handles and wheels and removable front/rear access doors for in-situ calibration in almost any environment
- Current output that extends to 120 A when paired with the 52120A Transconductance Amplifier
- Remarkably affordable
Fluke 5502A Multi-Product Calibrator
- Handheld and bench meters (analog and digital) to 4.5 digits
- Current clamps and clamp meters
- Panel meters
- Electronic thermometers
- Chart recorders
- Oscilloscope recorders
- XY recorders
- Data loggers
Fluke 5522A Multi-Product Calibrator
- Calibrates a wide variety of electrical test equipment
- Robust protection circuits prevent costly damage from operator error
- Resistance calibrator, voltage calibrator, current calibrator and more
- Redesigned carrying handles make the 5522A easy to transport
- Rugged optional carrying case with built-in handles and wheels and removable front/rear access doors for in-situ calibration in almost any environment
- Remarkably affordable
Fluke 5606 Full Immersion PRT
- 5606: -200 °C to 160 °C
- Calibration accuracy of ± 0.05 °C
- Transition junction and lead wires can withstand full PRT temperature range
- Unique probe seal of 5606 prevents ingress of moisture
- NVLAP-accredited calibration
Fluke 5610, 5611, 5611T, 5665 Temperature Probes, Reference Thermistor Probes
- Temperature probes with short-term accuracy to ± 0.01 °C; one-year drift < ± 0.01 °C
- Accredited NVLAP calibration optional
- Flexible PTFE and silicone coated fast-response models
- Rugged polished stainless steel sheaths
Fluke 5615 Secondary Reference Temperature Standards
- Affordable wide-range accuracy
- Calibrated accuracy ± 0.012 °C at 0 °C
- Reference-grade platinum sensing element
- NVLAP-accredited calibration included, lab code 200706-0