Fluke 5618B Small Diameter Industrial RTD
- Small diameter sheath, 3.2mm (0.125 in)
- Excellent stability
- Includes ITS-90 coefficients
- NVLAP-accredited calibrated from –200°C to 500°C, lab code 200706-0
Fluke 5622 Fast Response Platinum Resistance Thermometers (PRTs)
- Time constants as fast as 0.4 seconds
- NVLAP-accredited calibration, lab code 200348-0
- Small probe diameters ranging from 0.5 mm to 3.2 mm
Fluke 5623B Precision RTD Freezer Probe
- Fully immersible probe assembly to –100°C
- NVLAP-accredited calibration, lab code 200706-0, and ITS-90 coefficients included
- Accuracy to ±0.05°C over the full range
Fluke 5624 Platinum Resistance Thermometer to 1000 °C
- Temperature range of 0°C to 1000°C
- Accuracy (includes short-term stability and calibration uncertainty) of ±0.05°C to 962°C
- Long-term drift of 0.01°C at 0°C after 100 hours at 1000°C
- Designed by Fluke Calibration’s primary standards design team
Fluke 5626, 5628 Secondary Standard PRTs
- Range to 661°C
- Meets all ITS-90 requirements for resistance ratios
- Rtp drift < 20 mK after 500 hours at 661°C
- Calibrated accuracy of ± 0.006 °C at 0 °C
Fluke 5627A Precision Thermometer, RTD Temperature Probe
- Vibration and shock resistant
- NVLAP-accredited calibration included, lab code 200706-0
Fluke 5640 Series Thermistor Standards Probes
- Accuracy to ± 0.001 °C
- Affordable system accuracy to ± 0.004 °C or better
- NIST-traceable calibration included from manufacturer; accredited calibration from Fluke Calibration optional
Fluke 5681, 5683, 5684, and 5685 Quartz-Sheath SPRTs
- Drift rates as low as 0.0005 K
- Proprietary gas mixture ensures high stability
- Most experienced SPRT design team in the business
Fluke 5686-B Glass Capsule SPRT
- Temperatures from –260 °C (13 K) to 232 °C
- Stability typically 0.001 °C over 100 °C range
- Miniature capsule package eliminates stem conduction
Fluke 5698-25 Working Standard SPRT
- Conforms to ITS-90 SPRT guidelines
- Drift rate typically 0.003 °C
- Calibration options by fixed point
- Unmatched performance-to-price-ratio
Fluke 5699 High-Temperature Metal-Sheath SPRT
- Range to aluminum point (660 °C )
- Inconel™ and platinum sheaths guard against contamination
- Less than 8 mK/year drift
- Many calibration options available including by fixed point
- Fifth wire provides shield ground
Fluke 5725A Amplifier
- Frequency limits at higher voltage increase to 100 kHz at 750 V, 30 kHz at 1100 V
- Load limits are to 70 mA for frequencies above 5 kHz, and to 50 mA for frequencies less than 5 kHz
- Capacitive load limits are increased to 1000 pF