Fluke 5730A High Performance Multifunction Calibrator
- Improved performance specifications for ac voltage, ac current and resistance
- 6.5 inch VGA capacitive touch screen with full color graphical user interface
- Visual Connection Management™ output terminals guide connections
- Graphical user interface in nine languages
- Compatible with 52120A and 5725A amplifiers
- Full MET/CAL® compatibility with 5700A and 5720A procedures
- Artifact Calibration using 10 V, 1 Ω and 10 kΩ external standards; 30 MHz and 50 MHz wideband output options available
Fluke 5790B AC Measurement Standard
The 5790B covers an alternating voltage range of 600 μV to 1000 V, and a frequency range of 10 Hz to 1 MHz. Wideband voltage options extend frequency range to 30 or 50 MHz.
The 5790B in combination with the Fluke A40B Current Shunts now allow you to make direct, absolute or relative current measurements without the need to perform any calculations
Fluke 5901 Triple Point of Water Cells
- Easy-to-use, inexpensive standard with uncertainty better than ± 0.0001 °C
- Four sizes and two shells (glass and quartz) to choose from
- Isotopic composition of Vienna Standard Mean Ocean Water
Fluke 5960A Triple Point of Argon System
- Low uncertainty of 0.25 mK
- Temperature plateau duration longer than 30 hours
- Four entrant wells with radial uniformity less than 0.05 mK
- 480 mm total immersion depth
- Argon purity of 99.9999 %
- Multi-language display support
Fluke 6020/6022/6024 High Temperature Calibration Oil Baths
- Large-capacity tanks for higher productivity
- Calibrations up to 300 °C
- Built-in cooling coils for faster cooling
- Stability to ±0.001 °C
Fluke 6050H Extremely High Temperature Calibration Salt Bath
- Eliminates messy sand baths
- Electronically adjustable temperature cutouts
- Stability of ±0.008 °C at 550 °C
Fluke 6054/6055/7007 Deep-Well Baths
Extra-deep wells for thermometry work requiring extra tank depth and ultimate stability
- Constant liquid levels through concentric-tube design
- Special design for sighting LIG thermometers
- Depth up to 60 cm (24 in)
- Optional interface packages control all settings
Fluke 6102 – Liquid Bath Calibrator, 35 to 200°C
Fluke 6102-256Liquid Bath Calibrator, 35 to 200°C Offers
Features
- World’s smallest portable calibration baths can be transported with the fluid in them
- Stable to ±0.03°C or better, depending on the fluid you use
- Uniformity is ±0.02°C or better for low uncertainties using a reference thermometer
- Display accuracy has been improved to ±0.25°C for quick calibrations without a reference thermometer
- With a 48mm (1.9″) diameter, 140mm (5.5″) deep tank, user can calibrate any type of sensor including short, square, or odd-shaped sensors
Fluke 6102, 7102, 7103 Micro-Bath Thermometer Calibrators
- World’s smallest portable calibration baths
- Calibrates sensors of any size or shape
- Stability to ±0.015 °C
- Ranges from –30 °C to 200 °C
Fluke 6105A, 6100B Electrical Power Quality Calibrator
Wide workload coverage
The 6105A and 6100B cover a wide workload of electrical power test instruments, including:
- AC voltmeters
- AC ammeters
- Current transformers
- Flicker meters
- Phase angle meters
- Power factor meters
- Power analyzers
- Power recorders
- Power transducers-relay testers
- VA meters
- VAR meters
- Voltage transformers
- Wattmeters (3- or 4-wire)
- Watthour meters
- and more
Fluke 6109A – Portable Calibration Bath, 35°C to 250°C
Features
- Four times more calibration throughput with twice the accuracy of Micro-Baths and dry-block calibrators
- Calibrate up to four tri-clamp sanitary sensors at a time instead of just one
- Increase calibration efficiency and reduce production downtime.
- Excellent display accuracy of ±0.1°C provides 4:1 test uncertainty ratio (TUR) for critical applications
- Easy to transport up-stairs and across catwalks
- Clean room compatible. Stainless steel casing withstands sterilizing chemicals and is rust proof
Fluke 6135A/PMUCAL Phasor Measurement Unit Calibration System
The 6135A/PMUCAL system enables you to:
- Calibrate and test a PMU from a client PC, either at the site of the test system or remotely over the Internet
- Quickly set up a PMU test
- Speed through automated calibration procedures or interactively do custom PMU testing
- Provide the required static and dynamic voltage and current conditions that occur in a power distribution grid specified by the standard
- Apply those signals to a phasor measurement unit
- Capture the PMU’s reported results
- Evaluate the total vector error (TVE), frequency error (FE), and rate of change of frequency error (RFE)
- Compare those results with the original stimulus
- Evaluate against the thresholds defined in IEEE Std C37.118.1a™-2014
- Create test reports, graphs and calibration certificates that can be readily printed or shared electronically