Fluke 1523-P4-256 Single Channel Reference Thermometer Kit
Features
- Provides readings and graphs of recorded temperatures
- Stores up to 25 temperature readings in the integrated memory
- Large digital display clearly shows the results
Fluke 1524-P4-256 Dual Channel Reference Thermometer Kit
The kit provides reliable measurements and graphs of temperature readings. It records the measurements for later assessment.
Fluke 1550C Digital Insulation Resistance Tester with IR3000 FC Kit, 5kV
Features 1550C
- Quickly configure, start, and stop tests remotely, a safe distance away from any operating, energized equipment, using Fluke Connect® and a smartphone
- Real time trending gives you easy-to-see visual cues, rather than hard to read, rapidly changing values
- Automatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup
- Guard system eliminates the effect of surface leakage current on high-resistance measurements
- Selectable test voltages in 50 V steps from 250 to 1000 V, and 100 V steps above 1000 V
- CAT III 1000 V, CAT IV 600 V safety rating
- Warning function alerts the user that line voltage is present and gives the voltage reading up to 600 V AC or DC for increased user safety
- Measurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall
- Long battery life gives the user over 750 tests between charges
- Large digital/analog LCD for easy viewing
- Capacitance and leakage current measurement
- Ramp function for breakdown testing
- Resistance measurements up to 2 TΩ
- Timer settings up to 99 minutes for timed tests
Features IR3000FC Connector
- Fits over the IR port of your existing Fluke Tools
- Upgradeable by USB
- Immediately enables you to graph, save and share the tool’s reading with your team from your smart phone
Fluke 1550C Digital Insulation Resistance Tester with IR3000 FC, 5kV
Features Fluke 1550C
- Quickly configure, start, and stop tests remotely, a safe distance away from any operating, energized equipment, using Fluke Connect® and a smartphone
- Real time trending gives you easy-to-see visual cues, rather than hard to read, rapidly changing values
- Automatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup
- Guard system eliminates the effect of surface leakage current on high-resistance measurements
- Selectable test voltages in 50 V steps from 250 to 1000 V, and 100 V steps above 1000 V
- CAT III 1000 V, CAT IV 600 V safety rating
- Warning function alerts the user that line voltage is present and gives the voltage reading up to 600 V AC or DC for increased user safety
- Measurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall
- Long battery life gives the user over 750 tests between charges
- Large digital/analog LCD for easy viewing
- Capacitance and leakage current measurement
- Ramp function for breakdown testing
- Resistance measurements up to 2 TΩ
- Timer settings up to 99 minutes for timed tests
Features Fluke IR3000FC Connector
- Fits over the IR port of your existing Fluke Tools
- Upgradeable by USB
- Immediately enables you to graph, save and share the tool’s reading with your team from your smart phone
Fluke 1550C Digital Insulation Resistance Tester, 5kV
Features
- Quickly configure, start, and stop tests remotely, a safe distance away from any operating, energized equipment, using Fluke Connect® and a smartphone
- Real time trending gives you easy-to-see visual cues, rather than hard to read, rapidly changing values
- Automatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup
- Guard system eliminates the effect of surface leakage current on high-resistance measurements
- Selectable test voltages in 50 V steps from 250 to 1000 V, and 100 V steps above 1000 V
- CAT III 1000 V, CAT IV 600 V safety rating
- Warning function alerts the user that line voltage is present and gives the voltage reading up to 600 V AC or DC for increased user safety
- Measurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall
- Long battery life gives the user over 750 tests between charges
- Large digital/analog LCD for easy viewing
- Capacitance and leakage current measurement
- Ramp function for breakdown testing
- Resistance measurements up to 2 TΩ
- Timer settings up to 99 minutes for timed tests
Fluke 1550C/KIT Insulation Resistance Tester Kit, 5 kV
Features
- Quickly configure, start, and stop tests remotely, a safe distance away from any operating, energized equipment, using Fluke Connect® and a smartphone
- Real time trending gives you easy-to-see visual cues, rather than hard to read, rapidly changing values
- Automatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup
- Guard system eliminates the effect of surface leakage current on high-resistance measurements
- Selectable test voltages in 50 V steps from 250 to 1000 V, and 100 V steps above 1000 V
- CAT III 1000 V, CAT IV 600 V safety rating
- Warning function alerts the user that line voltage is present and gives the voltage reading up to 600 V AC or DC for increased user safety
- Measurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall
- Long battery life gives the user over 750 tests between charges
- Large digital/analog LCD for easy viewing
- Capacitance and leakage current measurement
- Ramp function for breakdown testing
- Resistance measurements up to 2 TΩ
- Timer settings up to 99 minutes for timed tests
Fluke 1551-CASE Carrying Case for 1551A Ex/1552A Ex Stik Thermometer Readouts
What’s included with the Fluke 1551-CASE
- Fluke 1551-CASE Carrying Case for 1551A Ex/1552A Ex Stik Thermometer Readouts
Fluke 1551-CBL RS-232 Cable for 1551A Ex/1552A Ex Stik Thermometer Readouts
What’s included with the Fluke 1551-CBL
- Fluke 1551-CBL RS-232 Cable for 1551A Ex/1552A Ex Stik Thermometer Readouts
Fluke 1551A-12 Intrinsically Safe Stik Thermometer, 12″, -58 to 320°F
Features
- Intrinsically-safe, battery operated, portable reference thermometer
- Provides accuracy of ±0.09°F (±0.05°C) over full range
- Features intrinsically-safe operation (ATEX and IECEx compliant)
- Measures -58 to 320°F (-50 to 160°C)
- Provides user-configurable temperature with Trend/Stability indicator
- Displays temperature in °C or °F
- Delivers 300-hour battery life
- Shows percent battery-life and low-battery indicators
Fluke 1551A-12-DL Intrinsically Safe Stik Thermometer with data logging, 12″, -58 to 320°F
Features
- Intrinsically-safe, battery operated, portable reference thermometer
- Provides accuracy of ±0.09°F (±0.05°C) over full range
- Features intrinsically-safe operation (ATEX and IECEx compliant)
- Measures -58 to 320°F (-50 to 160°C)
- Provides user-configurable temperature with Trend/Stability indicator
- Displays temperature in °C or °F
- Delivers 300-hour battery life
- Shows percent battery-life and low-battery indicators
Fluke 1551A-20 Intrinsically Safe Stik Thermometer, 20″, -58 to 320°F
Features
- Intrinsically-safe, battery operated, portable reference thermometer
- Provides accuracy of ±0.09°F (±0.05°C) over full range
- Features intrinsically-safe operation (ATEX and IECEx compliant)
- Measures -58 to 320°F (-50 to 160°C)
- Provides user-configurable temperature with Trend/Stability indicator
- Displays temperature in °C or °F
- Delivers 300-hour battery life
- Shows percent battery-life and low-battery indicators
Fluke 1551A-20-DL Intrinsically Safe Stik Thermometer with data logging, 20″, -58 to 320°F
Features
- Intrinsically-safe, battery operated, portable reference thermometer
- Provides accuracy of ±0.09°F (±0.05°C) over full range
- Features intrinsically-safe operation (ATEX and IECEx compliant)
- Measures -58 to 320°F (-50 to 160°C)
- Provides user-configurable temperature with Trend/Stability indicator
- Displays temperature in °C or °F
- Delivers 300-hour battery life
- Shows percent battery-life and low-battery indicators