Fluke 8588A Reference Multimeter
- 2.7 µV/V (95%), 3.5 µV/V (99%), 1 year relative accuracy, dc voltage without internal self-calibration or auto-adjustments
- 0.5 µV/V (95%), 0.65 µV/V (99%), 24 hour stability, dc voltage
- 7 µΩ/Ω (95%), 9 µΩ/Ω (99%), 1 year, resistance
- 2.02x full scale stretches lower noise floor to higher signal levels to maximize higher accuracies from the instrument
- 200 ns to 100 s aperture setting allows the industry’s widest flexibility to control data capture window
-3%
Close
Fluke 9009 – Dual Range Dry-Block Calibrator, Black
Fluke 9009 Dual Range Dry-Block Calibrator Offers
Features
- Two independently controlled temperature blocks, one for heating and one for cooling with a combined range of -15 to 350°C
- Unique dual unit allows you to calibrate your sensor in the heated well while the cool well stabilizes; this eliminates the need to wait for multiple temperature points during calibration
- Hot block provides temperatures from 50 to 350°C (122 to 662°F), while the cold block covers the range of -15 to 110°C (5 to 230°F)
- Each block is controlled by a precision Hart Scientific temperature controller
- Cold block is calibrated to within ±0.2°C with stability of ±0.05°C
- Hot block’s display is accurate to ±0.6°C with stability of ±0.05°C
- NIST-traceable calibration is included for each of the two test blocks
- Each temperature block includes two wells with removable inserts; calibrate four probes at once, or calibrate two probes at the same time with an external reference, or use the two temperature wells to get quick “zero” and “span” references for transmitter calibrations
Fluke 9009 Industrial Dual-Block Thermometer Calibrator
- Temperatures from –15 °C to 350 °C in one unit
- Two wells in each block for simultaneous comparison calibrations
- Rugged, lightweight, water-resistant enclosure
Fluke 9011 High-Accuracy Dual-Well Calibrator
- Combined range from –30 °C to 670 °C, one unit – two blocks
- Two independent temperature controllers (hot and cold side)
- Stability to ±0.02 °C
- Multi-hole wells for calibrating up to eight probes simultaneously
Fluke 908/909 Frequency References
- Accurate reference “Atomic clock” in automated test systems
- Affordable and very cost effective
- Designed for portability with optional carrying case
- No need for battery backup during transportation
- Fast warm-up time
Fluke 910/910R GPS Frequency Standards
- Unique traceability feature means no more re-calibrations
- Two high-stability models to meet your application, and fit your budget
- Up to 13 outputs, maximizing cost efficiency
- Central or remote monitoring, management and data collection, using the 910/910R Ethernet-port
- Two high-stability operating modes to suit your application
- Designed for portability too
- GPSView Software
Fluke 9100S – Dry Block Calibrator
Features
- Compact design
- Ranges from 95 to 707°F (35 to 375°C)
- Accuracy to ±0.25°C, stability of ±0.25°C at 122°F (50°C)
- RS-232 interface with 9930 Interface-it v3.81 software (Optional )
Fluke 9100S, 9102S Handheld Dry-Wells
- Smallest dry-wells in the world
- Ranges from –10°C to 375°C
- Accuracy to ±0.25°C, stability of ±0.05°C at 0°C
- RS-232 interface
Fluke 9101 Zero-Point Dry-Well
- Bath-quality stability in a portable ice-point reference
- Easy re-calibration for long-term reliability
- Ready-light frees user’s time and attention
- Solid-state cooling technology
-2%
Close
Fluke 9102S-256 Low Temperature Dry Block Calibrator
Features
- For work in the temperature range of -10 to 122°C
- Stable to ±0.05°C
- Includes a NIST-traceable calibration
- Excellent for dial gauges, digital thermometers, bulb switches, and other sensors that need calibration below ambient
- Two wells so you can use one for a reference thermometer to increase accuracy.
- Both wells are 1/2″ in diameter, and each has inserts available for almost any sensor size
- Battery pack option that gives you approximately four hours of field use when AC power is unavailable
- Removable insert sleeves 1/2″ O.D. x 4″ deep (13 mm x 102mm) and comes complete with 1/4″ and 3/16″ inserts (order additional insert sizes as needed)
Fluke 9103 – Low Temperature Field Drywell
Fluke 9103 Offers
Features
- Lightweight and very portable
- Accuracy to ±0.25°C
- Easy to recalibrate
Fluke 9103, 9140 Dry-Well Calibrators & Dry Block Calibrators
- Lightweight and very portable
- Accuracy to ±0.25 °C
- RS-232 interface
- Easy to recalibrate
Fluke 9114, 9115A, 9116A Freeze-point furnaces
- Designed to extend plateaus
- High-stability OEM controllers, RS-232 included
- External cooling coils
Fluke 9117 Annealing Furnace
- Guards against contamination
- Anneals both SPRTs and HTPRTs
- Fully programmable
Fluke 9118A Thermocouple Calibration Furnace
- Tube furnace configuration (without isothermal block): Base-metal thermocouples are often sheathed in formable materials such as braided fiberglass or PTFE. During calibration, they are bundled around a reference thermometer, held together with fiberglass cord or tape, and inserted into a tube furnace.
- Isothermal block configuration: Metal- or ceramic-sheathed thermocouples are generally constructed with noble-metal thermoelements and therefore have higher calibration accuracy requirements. The isothermal block, which accommodates up to four 6.35 millimeter probes, improves heat transfer and temperature stability. This better equalizes the temperature between the reference probe and the UUT, which lowers measurement uncertainty compared to calibration without a block.
-7%
Close
Fluke 9132 – Portable Infrared Calibrator 50C to 500C
- Certify IR pyrometers from –30 °C to 500 °C (–22 °F to 932 °F)
- Large 57 mm (2.25 in) blackbody target
- RTD reference well for contact temperature measurement
- Small, compact design in a blackbody calibrator
Fluke 9142 – Field Metrology Wells
Key Features:
- Lightweight, portable, and fast
- Cool to –25 °C in 15 minutes and heat to 660°C in 15 minutes
- Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current
- True reference thermometry with accuracy to ±0.01 °C
- On-board automation and documentation
- Metrology performance in accuracy, stability, uniformity, and loading
Fluke 9142, 9143, 9144 Field Metrology Wells
- Lightweight, portable, and fast
- Cool to –25 °C in 15 minutes and heat to 660°C in 15 minutes
- Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current
- True reference thermometry with accuracy to ±0.01 °C
- On-board automation and documentation
- Metrology performance in accuracy, stability, uniformity, and loading
Fluke 9143 – Mid Temperature Field Drywell
Key features
- Lightweight, portable, and fast
- Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current
- True reference thermometry with accuracy to ±0.01 °C
- On-board automation and documentation
- Metrology performance in accuracy, stability, uniformity, and loading
Fluke 9144 – High Temperature Field Drywell
Key features
- Lightweight, portable, and fast
- Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current
- True reference thermometry with accuracy to ±0.01 °C
- On-board automation and documentation
- Metrology performance in accuracy, stability, uniformity, and loading
Fluke 9150 Thermocouple Furnace
- Temperature range to 2192°F (1200°C) with a stability of ±0.5°C, and display accuracy of ±5°C across its entire range
- Uses Hart’s microprocessor-based controller for great stability and set-point accuracy
- Rapid cool-down and heat-up times
- Interchangeable multiple hole probe sleeves
- Eight set-point memory
- Adjustable readout in °C or °F
- RS-232 port for connection to a PC
Fluke 9170, 9171, 9172, & 9173 Metrology Well Calibrators
- Best-performing industrial heat sources (accuracy, stability, uniformity) in the world
- Immersion depth to 203 mm (8 in)
- Optional ITS-90 reference input reads PRTs to ±0.006 °C
- Temperature range from –45 °C to 700 °C
Fluke 9190A Ultra-Cool Field Metrology Well
Wide temperature range
–95 °C to 140 °C
Excellent accuracy
Accuracy using built-in reference thermometer readout: ± 0.05 °C full range
Display accuracy: ± 0.2 °C full range
Best-in-class stability
± 0.015 °C full range
Fast cooling time
23 °C to –90 °C: 80 minutes
23 °C to –95 °C: 90 minutes
140 °C to 23 °C: 60 minutes
Fluke 9210 Mini Triple Point of Water Maintenance Apparatus
- Easy preprogrammed realization
- Inexpensive fixed-point solution
- Training takes a few hours