Fluke 8588A Reference Multimeter
- 2.7 µV/V (95%), 3.5 µV/V (99%), 1 year relative accuracy, dc voltage without internal self-calibration or auto-adjustments
- 0.5 µV/V (95%), 0.65 µV/V (99%), 24 hour stability, dc voltage
- 7 µΩ/Ω (95%), 9 µΩ/Ω (99%), 1 year, resistance
- 2.02x full scale stretches lower noise floor to higher signal levels to maximize higher accuracies from the instrument
- 200 ns to 100 s aperture setting allows the industry’s widest flexibility to control data capture window
Fluke 9009 – Dual Range Dry-Block Calibrator, Black
Fluke 9009 Dual Range Dry-Block Calibrator Offers
Features
- Two independently controlled temperature blocks, one for heating and one for cooling with a combined range of -15 to 350°C
- Unique dual unit allows you to calibrate your sensor in the heated well while the cool well stabilizes; this eliminates the need to wait for multiple temperature points during calibration
- Hot block provides temperatures from 50 to 350°C (122 to 662°F), while the cold block covers the range of -15 to 110°C (5 to 230°F)
- Each block is controlled by a precision Hart Scientific temperature controller
- Cold block is calibrated to within ±0.2°C with stability of ±0.05°C
- Hot block’s display is accurate to ±0.6°C with stability of ±0.05°C
- NIST-traceable calibration is included for each of the two test blocks
- Each temperature block includes two wells with removable inserts; calibrate four probes at once, or calibrate two probes at the same time with an external reference, or use the two temperature wells to get quick “zero” and “span” references for transmitter calibrations
Fluke 9009 Industrial Dual-Block Thermometer Calibrator
- Temperatures from –15 °C to 350 °C in one unit
- Two wells in each block for simultaneous comparison calibrations
- Rugged, lightweight, water-resistant enclosure
Fluke 9011 High-Accuracy Dual-Well Calibrator
- Combined range from –30 °C to 670 °C, one unit – two blocks
- Two independent temperature controllers (hot and cold side)
- Stability to ±0.02 °C
- Multi-hole wells for calibrating up to eight probes simultaneously
Fluke 908/909 Frequency References
- Accurate reference “Atomic clock” in automated test systems
- Affordable and very cost effective
- Designed for portability with optional carrying case
- No need for battery backup during transportation
- Fast warm-up time
Fluke 910/910R GPS Frequency Standards
- Unique traceability feature means no more re-calibrations
- Two high-stability models to meet your application, and fit your budget
- Up to 13 outputs, maximizing cost efficiency
- Central or remote monitoring, management and data collection, using the 910/910R Ethernet-port
- Two high-stability operating modes to suit your application
- Designed for portability too
- GPSView Software
Fluke 9100S – Dry Block Calibrator
Features
- Compact design
- Ranges from 95 to 707°F (35 to 375°C)
- Accuracy to ±0.25°C, stability of ±0.25°C at 122°F (50°C)
- RS-232 interface with 9930 Interface-it v3.81 software (Optional )
Fluke 9100S, 9102S Handheld Dry-Wells
- Smallest dry-wells in the world
- Ranges from –10°C to 375°C
- Accuracy to ±0.25°C, stability of ±0.05°C at 0°C
- RS-232 interface
Fluke 9101 Zero-Point Dry-Well
- Bath-quality stability in a portable ice-point reference
- Easy re-calibration for long-term reliability
- Ready-light frees user’s time and attention
- Solid-state cooling technology
Fluke 9102S-256 Low Temperature Dry Block Calibrator
Features
- For work in the temperature range of -10 to 122°C
- Stable to ±0.05°C
- Includes a NIST-traceable calibration
- Excellent for dial gauges, digital thermometers, bulb switches, and other sensors that need calibration below ambient
- Two wells so you can use one for a reference thermometer to increase accuracy.
- Both wells are 1/2″ in diameter, and each has inserts available for almost any sensor size
- Battery pack option that gives you approximately four hours of field use when AC power is unavailable
- Removable insert sleeves 1/2″ O.D. x 4″ deep (13 mm x 102mm) and comes complete with 1/4″ and 3/16″ inserts (order additional insert sizes as needed)
Fluke 9103 – Low Temperature Field Drywell
Fluke 9103 Offers
Features
- Lightweight and very portable
- Accuracy to ±0.25°C
- Easy to recalibrate
Fluke 9103, 9140 Dry-Well Calibrators & Dry Block Calibrators
- Lightweight and very portable
- Accuracy to ±0.25 °C
- RS-232 interface
- Easy to recalibrate